| Technical data |
| Application | Emergency stop, Light barrier |
| Cat. / PL acc. to EN ISO 13849-1 | 2/d |
| SIL CL acc. to IEC/EN 62061 | 2 |
| SIL acc. to IEC/EN 62061 | 2 |
| Width | 22,5 mm |
| Type | BG 5914.08/_0___ |
| Variant |
| Contact equipping | 8 potential free inputs |
| Nominal voltage | DC 24 V |
| Approvals and Markings | CSA C/US, TÜV |
The Dold input module BG5914.08/00MF0 DC24V is a modular safety component for implementing safety-related control circuits in machine and plant engineering. It is used for monitoring emergency stop functions and light grids and is part of the SAFEMASTER M system, developed for the safe control of machines and production lines. The module features 8 potential-free inputs and is designed for a nominal voltage of DC 24 V. It complies with safety requirements according to EN ISO 13849-1 with Performance Level (PL) d and Category 2, as well as IEC/EN 62061 with SIL CL 2 and SIL 2. The CSA C/US and TÜV certifications confirm compliance with relevant safety standards.
Applications
This module is designed for industrial applications, particularly in the paper and printing industry, forming technology, beverage, food, and packaging industries, as well as in robotics cells, machine tools, and production lines. It is suitable for monitoring emergency stop switches, safety doors, light barriers, light grids, and two-hand controls in accordance with EN 574 IIIA/IIIC. The functions can be used in both automatic and setup modes, for example, for troubleshooting, maintenance, or adjustment operations.
Functions and Equipment in Detail
The module enables various configurations: up to 8 single-channel emergency stop switches, or combinations of single- and dual-channel emergency stop switches and alarm inputs, can be monitored. The start function can be configured as either auto-start or manual start. Instead of a dual-channel emergency stop switch, a non-contact safety device (BWS) Type 4, such as a light barrier, can also be connected. The integrated wire break and short-circuit monitoring ensures reliable fault detection, with fault indication provided via LEDs and semiconductor outputs.
Technology Explained Simply
The 8 potential-free inputs allow connection of safety contacts, which are monitored independently. The nominal voltage of DC 24 V is a common voltage in industrial automation and ensures stable power supply. The safety functions are certified according to EN ISO 13849-1 (PL d, Cat. 2) and IEC/EN 62061 (SIL 2), confirming suitability for safety-critical applications. The module width of 22.5 mm allows compact mounting in standard control panels. Status indication is provided via LEDs and two semiconductor outputs per module, which can be used for diagnostics and system monitoring.
Compatibility and Accessories
The module is part of the SAFEMASTER M system and can be combined with other modules in this system to implement complex safety functions. It is suitable for use with output modules and optional fieldbus connection to transmit system status to other bus participants. The assignment of input to output functions is done via internal switches, without requiring programming. The modular expandability allows flexible adaptation to different monitoring tasks.
Mounting and Installation
The module is mounted in standard control panels, with the width of 22.5 mm ensuring compact placement. Wiring is done via the designated terminal clamps. Functions are configured using internal switches, with settings adjusted using a screwdriver. Installation does not require a special programming environment, as function assignment is mechanical.
Operational Advantages
The module offers a flexible and cost-efficient solution for implementing safety-related functions. Simple configuration without programming reduces setup time and maintenance costs. Integrated diagnostics via LEDs and semiconductor outputs enable quick fault localization. The modular design and expandability support application-specific adaptation and future system extensions. The CSA C/US and TÜV certifications ensure compliance with international safety standards.