| Technical data |
| Application | Emergency stop, Light barrier, Safety gate, Two-hand |
| Cat. / PL acc. to EN ISO 13849-1 | 4/e |
| SIL CL acc. to IEC/EN 62061 | 3 |
| SIL acc. to IEC/EN 62061 | 3 |
| Safety integrity level according to EN 574 | lll C |
| Width | 22,5 mm |
| Type | BG 5913.08/_1___ |
| Variant |
| Contact equipping | 8 inputs for control units |
| Nominal voltage | DC 24 V |
| Approvals and Markings | CSA C/US, TÜV |
The Dold BG5913.08/01MF0 DC24V is an
input module for the modular safety system SAFEMASTER M, designed for implementing safety-related control circuits in machine and plant engineering. It is used for monitoring and controlling safety functions such as emergency stop, safety doors, light grids, and two-hand controls. The device is designed for operation with a nominal voltage of
DC 24 V and has a width of
22.5 mm, making it suitable for use in standard DIN control panels. The functions can be selected via rotary switches, enabling simple, software-free configuration without a programming device.
Applications
This module is used in industrial applications where the safety of personnel and machines is paramount. Typical applications include monitoring of light barriers, emergency stop circuits, safety doors, and two-hand controls type IIIC according to DIN/EN 574. It is particularly suitable for machines in the paper and printing industry, forming technology, food and beverage processing, as well as in robotics cells and production lines. The modular design allows flexible adaptation to different monitoring tasks and system expandability.
Functions and Equipment in Detail
The module features
8 inputs for command devices, intended for connecting safety switches, light grids, or other command units. It provides
2 semiconductor outputs for status indication, which can be used to monitor the system status. The integrated
wire break and short-circuit monitoring with fault indication ensures reliable functional control of connected sensors. Status indications are provided via
LEDs, visually signaling the operating status. Functions such as manual/automatic start, cross-circuit detection, and selection between immediate or delayed switching behavior can be set via internal switches.
Technology Explained Simply
The device is designed as a
safety-related input circuit, processing signals from command devices and making safety-critical decisions. The
Performance Level (PL) e and
Category 4 according to EN ISO 13849-1 guarantee a high safety performance required for critical applications. The
SIL requirement limit (SIL CL) 3 according to IEC/EN 62061 and
SIL 3 certification according to IEC/EN 61508 confirm suitability for safety-critical control tasks. The
Safety Level Class III C according to EN 574 makes the module suitable for two-hand controls, requiring simultaneous actuation of two buttons to enter a hazardous zone.
Compatibility and Accessories
The module is part of the SAFEMASTER M system and can be combined with other modules such as output modules, expansion modules, or an optional fieldbus interface. The assignment of input to output functions is done via internal switches, enabling flexible and hierarchical group formation. System messages can be transmitted via the optional fieldbus interface to other bus participants, allowing the system status to be displayed in a higher-level control system.
Mounting and Installation
Mounting is done in standard DIN control panels with a width of 22.5 mm. Wiring is done via screw terminals, with the terminal assignment corresponding to the technical specifications. Function configuration is done via rotary switches, adjusted with a screwdriver. No programming is required, simplifying commissioning.
Operational Advantages
The module offers
software-free configuration, eliminating the need for special programming devices or software tools. Simple function selection via switches reduces commissioning time and minimizes error sources. The integrated diagnostic function with LEDs and semiconductor outputs enables quick fault detection. Modular expandability and flexible adaptation to different safety requirements make the system a cost-efficient alternative to conventional safety components.
Approvals and Markings
The device carries the approvals
CSA C/US and
TÜV, confirming compliance with applicable safety standards for use in North America and Europe. The approvals relate to the safety functions and electrical safety of the device.
Application-Specific Features
The module is designed for implementing emergency stop circuits, safety door monitoring, two-hand controls type IIIC, and non-contact safety devices such as light grids. The functions are selectable via rotary switches, allowing flexible adaptation to the specific application. The integrated diagnostic function enables quick fault detection and correction during operation.
System Integration
The module can be integrated into existing safety systems and operates as part of the SAFEMASTER M system. The assignment of input to output functions is done via internal switches, enabling flexible and hierarchical group formation. System messages can be transmitted via the optional fieldbus interface to other bus participants, allowing the system status to be displayed in a higher-level control system.
Safety Functions
The safety functions include monitoring of emergency stop circuits, safety doors, light grids, and two-hand controls. The functions are selectable via rotary switches, allowing flexible adaptation to the specific application. The integrated diagnostic function enables quick fault detection and correction during operation.