| Technical data |
| Cat. / PL acc. to EN ISO 13849-1 | 4/e |
| SIL CL acc. to IEC/EN 62061 | 3 |
| SIL acc. to IEC/EN 62061 | 3 |
| Safe output contacts, redundant NO contacts | 3, 4 |
| Safe output contacts, time delay | 2, 3 |
| Width | 22,5 mm |
| Type | BG 5912 |
| Variant |
| Contact equipping | 4 NO contacts |
| Nominal voltage | DC 24 V |
| Time range | without |
| Approvals and Markings | CSA C/US, TÜV |
The Dold BG5912.04/00000 DC24V is an output module for the modular safety system SAFEMASTER M. It is designed for implementing safety-oriented control circuits that ensure the protection of personnel and machinery in industrial operations. The module is intended for use in machine and plant engineering, particularly in sectors such as the paper and printing industry, forming technology, and the food and packaging industry. It enables the control of safety functions such as emergency stop, protective doors, light barriers, or two-hand controls, with functions being easily configured via switches within the module, without requiring special programming software.
Safety functions and certifications
The module meets the requirements of safety category 4 and performance level e according to EN ISO 13849-1. It is also certified for use in systems with safety integrity level (SIL) 3 according to IEC/EN 62061 and IEC/EN 61508. These certifications guarantee that the device can be used in safety-critical applications where high reliability and fault detection are required. The CSA C/US and TÜV certifications confirm compliance with international and European safety standards.
Functions and equipment in detail
The module features a contact configuration with 4 normally open (NO) contacts, suitable for the safe control of loads such as motors, valves, or warning lights. The output contacts are redundantly designed, supporting configurations with 3 or 4 redundant NO contacts. This increases the fault tolerance and safety of the system. The contacts can switch without time delay, with variants also available featuring a time delay of 2 to 3 seconds to enable controlled shutdown. A continuously monitored feedback circuit ensures monitoring of external contact amplification, guaranteeing correct operation of the outputs.
Technology explained clearly
The module width of 22.5 mm allows for compact mounting in standard 35 mm control panels. The rated voltage is DC 24 V, a common voltage in industrial electronics. Integrated LEDs serve as status indicators and enable quick diagnosis of the operating state. The module functions can be easily adjusted using internal switches and a screwdriver, without requiring special tools or software. The assignment of input and output functions is flexible, allowing complex safety functions to be implemented without extensive wiring effort.
Compatibility and accessories
The module is part of the SAFEMASTER M system and can be combined with other modules such as input modules, control units, or expansion modules. System components can be hierarchically grouped and flexibly adapted to specific monitoring tasks. The optional fieldbus connection enables the transmission of system status to other bus participants, supporting integration into existing automation systems. The modular architecture allows for scalable expansion, enabling the system to adapt to growing requirements.
Mounting and installation
Mounting is done in standard control panels with 35 mm mounting rails. The module width of 22.5 mm allows for dense arrangement of multiple modules. Wiring is done via screw terminals, ensuring a secure and reliable electrical connection. Function configuration is performed using internal switches operated with a screwdriver. No special programming or programming device is required.
Advantages in operation
The module offers a cost-effective alternative to conventional or programmable safety components. The simple configuration without software reduces setup time and training costs. Integrated diagnostics via LEDs and semiconductor alarm outputs enable rapid fault detection. The modular design and flexible function assignment simplify the planning and implementation of complex safety requirements. The system is suitable for use in mobile and stationary machines as well as production lines, with safety functions being effective in both automatic and setup modes.