Dold 0056174 emergency stop module BH5928.47/61 AC/DC24V 0.5-5S

Dold 0056174 emergency stop module BH5928.47/61 AC/DC24V 0.5-5S

Lieske Part No. 1001958
Mfg Part No 0056174
EAN-Code 4030641561741
Manufacturer Dold
Here only 507,41 EUR
603,82 EUR incl. VAT

Further information for Dold 0056174 emergency stop module BH5928.47/61 AC/DC24V 0.5-5S

Technical data
1- / 2-channel1, 2
ApprovalsUL
Cat. / PL acc. to EN ISO 13849-14/e
ConnectionPluggable screw terminals
Output contacts max.3 NO contacts, 3 NO contacts delayed
SIL CL acc. to IEC/EN 620613
SIL acc. to IEC/EN 620613
Thermal current Ith max.5 A
Width45 mm
TypeBH 5928
Cross fault detectionYes
Suited as safety gate monitorYes
Variant
Contact equipping3 NO contacts, 1 NC contact instantaneous, 1 NO contact off delay
Nominal voltageAC/DC 24 V
Time range0,5 - 5 s
Approvals and MarkingsUL-listed C/US, TÜV, CCC
VariantWith adjustable time delay
The Dold BH5928.47/61 AC/DC24V 0,5-5S is an emergency stop module with adjustable time delay, specifically designed for use in safety-critical systems in industrial environments. It serves as a protective function for personnel and machinery, particularly in emergency stop circuits where a Stop Category 1 must be implemented. The device is suitable as a safety door monitor and monitors, for example, sliding safety grilles, ensuring that machines can only be started when all safety measures are properly activated. The width is 45 mm, enabling compact installation in standard control panels.

Applications
This module is used in systems requiring high safety standards, such as in manufacturing, packaging, or machinery with moving parts. It is suitable for use in 1- or 2-channel circuits, allowing flexible integration into various safety concepts. The function as a safety door monitor enables monitoring of access protection systems to ensure the machine can only be started when the safety grille is closed.

Functions and Equipment in Detail
The device features contact configuration with 3 normally closed contacts, 1 immediate normally open contact, and 1 delayed normally closed contact. The time delay is adjustable in the range of 0.5 to 5 seconds, allowing the reset time of the contact to be adapted to the requirements of the respective system. The status indicator for the delayed time circuit enables visual monitoring of the operating state. LED indicators for power, channel 1/2, and time delay support diagnostics and maintenance. The cross-circuit detection at the single-button (when connected to terminals S33–S34) detects wire breaks or short circuits in the control circuit, increasing safety.

Technology Explained Simply
The module’s function is based on monitoring safety functions in machines. When the emergency stop button is activated, the switching process is initiated, with the delayed contacts remaining open for a defined time (0.5–5 s) before closing. This allows, for example, controlled deceleration or a safe stop of the machine. The connection technology uses removable screw terminals, enabling flexible and secure connections. Wire connection options include 2 x 1.5 mm² stranded wire with sleeve and plastic collar DIN 46 228-1/-2/-3/-4 or 2 x 2.5 mm² stranded wire with sleeve DIN 46 228-1/-2/-3. Activation occurs either via the single-button at S33–S34 or via an automatic start function with a bridge at S13–S14.

Compatibility and Accessories
The module is designed for operation with a nominal voltage of AC/DC 24 V. It is rated for a thermal current load of up to 5 A, defining the contact load capacity. Certifications include UL-listed C/US, TÜV, and CCC, confirming compliance with international safety standards. Safety integrity is ensured by certification according to EN ISO 13849-1 (Category 4, Performance Level e) and IEC/EN 62061 (SIL CL 3, SIL 3). These certifications are essential for use in safety-critical systems.

Mounting and Installation
Mounting is done in standard control panels with a width of 45 mm. The removable terminal blocks simplify installation and maintenance. The connection terminals are clearly labeled, supporting error-free wiring. The device indicators (LEDs) allow for quick visual inspection of the operating state. Cross-circuit detection is selectable via terminals, enabling flexible configuration.

Advantages in Operation
The module offers high safety integrity through certifications according to EN ISO 13849-1 and IEC/EN 62061. The adjustable time delay allows adaptation to specific machine requirements. Status indicators and LED indicators simplify diagnostics and maintenance. Removable terminals and clear labeling of connection terminals reduce installation errors. Compatibility with 1- and 2-channel circuits increases flexibility when integrating into existing safety concepts.