Further information for Dold 0055649 IL5881.12 DC12-280V UH DC24V insulation monitor 5-200 kΩ
Technical data
Enclosure design
Distribution board
IMD type
DC
Nominal voltage IT system
DC 12 - 280 V, DC 24 - 500 V
Response value
5 - 500 kΩ
Response value type
Adjustable
Width
35 mm
Type
IL 5881
Earth fault indicator
Variant
Alarm value
5 - 200 kOhm
Auxiliary voltage
DC 24 V
Contact equipping
2 changeover contacts
Nominal voltage
DC 12 - 280 V
Time delay
without
Approvals and Markings
UKCA, CCC
The insulation monitor IL5881.12 DC12-280V UH DC24V from Dold is a device for monitoring the insulation resistance in ungrounded DC networks (IT systems) with a nominal voltage of DC 12 to 280 V. The device is designed for early detection of earth faults to ensure preventive fire and system protection, particularly in industrial and railway applications. The supply voltage (auxiliary voltage) is drawn directly from the monitored network, eliminating the need for a separate power supply. Operational readiness is indicated by a green LED, while red LEDs indicate earth faults on L+ or L-, enabling selective fault localization.
Applications
The insulation monitor is designed for pure DC networks operating in the range of DC 12 to 280 V. It is particularly suitable for installations where interruption of power supply is not acceptable, such as in industrial production plants, railway or vehicle technology. Monitoring is performed according to the rest current principle, where the output relay drops out in case of a fault, ensuring a safe response to insulation faults.
Functions and Equipment in Detail
The device features two changeover contacts as contact configuration, which can be used for controlling alarm signals or switching operations. The alarm threshold for earth fault is adjustable and ranges from 5 to 200 kOhm. Adjustment is user-friendly via a potentiometer on the front of the device. Earth fault indication is provided by LED indicators, with the red LED indicating L+ and the other indicating L-, to identify the fault source. Additionally, internal reset and test buttons are available, which can also be connected externally.
Technology Explained Simply
The insulation monitor supervises the asymmetric insulation resistance between conductors L+ and L- relative to ground. When the resistance falls below the set alarm threshold, the fault is indicated by the LEDs and the relay switches off. The function can be programmably set to memory or hysteresis behavior. With hysteresis behavior, the device automatically resets when the insulation resistance rises above the alarm threshold again. Without hysteresis behavior, the fault condition is stored until reset via the reset button.
Compatibility and Accessories
The device is manufactured in the IL 5881 form factor, featuring a depth of 61 mm and bottom-mounted connection terminals for installation and industrial distributors according to DIN 43880. It is suitable for DIN rail or screw mounting and has a width of 35 mm. Monitoring is performed in accordance with the standard IEC/EN 61557-8. For special applications, a variant with separate auxiliary voltage and a measurement range of 20 to 500 kOhm is available upon request, but is not part of this version.
Mounting and Installation
Mounting is done either on a DIN rail or by screw fastening. The connection terminals are located at the bottom, facilitating integration into standard installation distributors. Terminal designations include A1 (L/+), A2 (N/-), PE (protective conductor), PT/X1 (test button), and LT/X1 (reset and clear function). Cable connections are made directly to the terminals, with the auxiliary voltage drawn from the monitored network.
Operational Advantages
Selective earth fault detection for L+ and L- allows for quick fault localization, reducing maintenance time. The simple adjustment of the trigger threshold via the potentiometer enables application-specific adaptation. Integrated LEDs provide clear visual indication of the operational status, accelerating diagnosis in case of faults. The device is designed for use in IT systems requiring high availability, thus offering reliable protection against insulation faults.
Approvals and Markings
The device carries UKCA and CCC approvals, confirming compliance with applicable safety and quality requirements in the respective markets. Compliance with the standard IEC/EN 61557-8 ensures reliability and interoperability in industrial applications.
Width and Enclosure Form
The width is 35 mm, enabling compact mounting in standard distributor enclosures. The enclosure form is designed for installation distributors, with terminals located at the bottom to simplify integration into existing control systems. Mounting is either on DIN rail or by screws, depending on installation requirements.
IMD Type and Nominal Voltage
The IMD type is DC, confirming use in DC networks. The nominal voltage of the monitored IT system is in the range of DC 12 to 280 V. The auxiliary voltage is drawn from the network and is DC 24 V. The trigger thresholds are adjustable and range from 5 to 500 kΩ, with the range 5 to 200 kΩ applying to this variant.
Indication and Operation
Indication is provided via LEDs: the green LED indicates operational readiness, while the red LEDs indicate earth faults on L+ (RE+) or L- (RE-). Operation is performed via integrated reset and test buttons, which can also be connected externally. The test button simulates an earth fault to test the device's functionality.
Functional Safety and Reliability
The device operates on the rest current principle, where the output relay drops out in case of a fault. This ensures a safe response to insulation faults. The programmable selection between memory and hysteresis behavior allows for application-specific configuration. Integrated functions such as reset and test buttons, as well as selective fault indication, increase the reliability and maintainability of the system.