Technical data
1- / 2-channel
1, 2
Approvals
UL
Cat. / PL acc. to EN ISO 13849-1
4/e
Connection
Pluggable screw terminals
Output contacts max.
3 NO contacts, 3 NO contacts delayed
SIL CL acc. to IEC/EN 62061
3
SIL acc. to IEC/EN 62061
3
Thermal current Ith max.
5 A
Width
45 mm
Type
BH 5928
Cross fault detection
Suited as safety gate monitor
Variant
Contact equipping
3 NO contacts, 3 NO contacts off delay
Nominal voltage
AC/DC 24 V
Time range
0,5 - 5 s
Approvals and Markings
UL-listed C/US, TÜV, CCC
Variant
With adjustable time delay
The Dold safety relay BH5928.93/61 AC/DC24V 0.5-5S is an emergency stop module for use in safety-critical industrial applications. It serves as a protective function for personnel and machinery, particularly for implementing emergency stop circuits according to Stop Category 1. The device is suitable as a safety door monitor and can monitor, for example, sliding safety grilles. It features an adjustable time delay ranging from 0.5 to 5 seconds, which can be used for controlled shutdown of machines or systems. The width is 45 mm, enabling compact mounting in standard control panels.
Applications
This safety relay is designed for applications in industrial automation where safe shutdown is required in hazardous situations. It is used to implement emergency stop functions in machines and systems, especially in environments where immediate response to threats is necessary. Its function as a safety door monitor makes it suitable for systems with movable safety grilles, where opening the door triggers an immediate shutdown. Compliance with safety standards such as EN ISO 13849-1 and IEC/EN 62061 ensures reliability in critical processes.
Functions and Equipment in Detail
The device features contact configuration with 3 normally open contacts (immediate contacts) and 3 delayed-closing contacts. The delayed-closing contacts enable controlled shutdown, remaining active for a defined period (0.5 to 5 seconds) after triggering the emergency stop function. Connection is made via removable screw terminals, allowing flexible and secure wiring. The terminal connections support up to 2 x 1.5 mm² stranded wire with sleeve and plastic collar DIN 46 228-1/-2/-3/-4 or 2 x 2.5 mm² stranded wire with sleeve DIN 46 228-1/-2/-3. Status indication for the delayed timing circuit, as well as LED indicators for power supply, channel 1/2, and time delay, support diagnostics and maintenance.
Technology Explained Simply
The safety relay operates at a rated voltage of AC/DC 24 V and is designed for 1- or 2-channel wiring. Cross-connection detection at the single-button (when connected to terminals S33–S34) detects faults in the control circuit to avoid false alarms or unintended shutdowns. The choice between activation via the single-button at S33–S34 or automatic start function with a bridge at S13–S14 offers flexibility in control. The thermal current rating is up to 5 A, defining the contact load capacity. The safety functions are certified according to standards EN ISO 13849-1 (Performance Level PL e, Category 4) and IEC/EN 62061 (SIL CL 3), ensuring reliability in safety-critical applications.
Compatibility and Accessories
The device can be combined with various safety components, particularly in systems requiring emergency stop functions and safety door monitoring. The terminal connections allow flexible integration into existing circuits. Certifications UL-listed C/US, TÜV, and CCC confirm compliance with international safety standards. Use in combination with other Dold safety modules is possible, with the exact configuration varying depending on the application scenario.
Mounting and Installation
Mounting is done in standard control panels with a width of 45 mm. The removable screw terminals facilitate installation and maintenance. The terminals are clearly labeled to ensure error-free wiring. The LED indicators support commissioning and diagnostics by visually displaying the operating status. Adherence to the specifications in the datasheet is required for safe and reliable operation.
Advantages in Operation
The adjustable time delay enables customized shutdown, which can be optimized according to the application. Cross-connection detection increases safety by identifying faults in the control circuit. The clear status indication and LED indicators simplify maintenance and fault diagnosis. Certifications according to EN ISO 13849-1 and IEC/EN 62061 guarantee compliance with safety requirements in industrial installations. The combination of compact design and comprehensive safety functions makes the device a reliable solution for emergency stop applications.