Dold 0055138, EAN: 4030641551384

Dold 0055138 IL5882.38 residual current device AC/DC24-230V 10A

Industrial Material > Industrial relays and contactors > Industrial Relays

Dold 0055138 IL5882.38 residual current device AC/DC24-230V 10A

Lieske Part No. 1313028
Mfg Part No 0055138
EAN-Code 4030641551384
Manufacturer Dold
Here only 312,66 EUR
372,07 EUR incl. VAT

Further information for Dold 0055138 IL5882.38 residual current device AC/DC24-230V 10A

Technical data
Adjustable measuring ranges0,01 - 10 A, 0,01 - 30 A
ClassificationType A (AC, DC pulsating)
Enclosure designDistribution board
Type of voltageAC, DC pulsating
Width35 mm
TypeIL 5882
Broken conductor detectionYes
Clear keyYes
Operate delayYes
Relay contact / outputYes
Test keyYes
Variant
Auxiliary voltageAC/DC 24 - 230 V
Contact equipping1 changeover contact for prewarning, 1 changeover contact for alarm
Measuring range10 A
Time delay5 s
Approvals and MarkingsUKCA, CCC
The Dold differential current monitor IL5882.38 is an industrial monitoring protection device used for detecting insulation faults in earthed electrical networks. The device enables continuous monitoring and preventive maintenance of systems, allowing early detection of insulation degradation without immediately causing operational interruption. It is designed for use in installation and industrial distributors according to DIN 43880 and features a width of 35 mm. The auxiliary voltage can operate in the range AC/DC 24 to 230 V, enabling flexible integration into existing systems.

Applications
IL5882.38 is intended for monitoring electrical systems in earthed networks, particularly in industrial and production environments where high availability and preventive protection against fires or equipment damage are required. It is suitable for early detection of insulation faults caused by aging, contamination, or mechanical damage. The device is used in conjunction with an external differential current transformer, such as the ND 5016, ND 5019, or the hinged current transformer ND 5014, which encloses the conductors to be monitored (excluding PE).

Functions and Equipment in Detail
The device features two relay outputs: one changeover contact for pre-warning and one changeover contact for alarm. The pre-warning is activated when a lower threshold value is reached, while the alarm is triggered when the higher threshold value is reached. The response thresholds are adjustable in 9 steps, with measurement ranges of 0.01 to 10 A or 0.01 to 30 A. The time delay is set to 5 seconds by default and is adjustable to avoid unwanted triggering due to pulsating fault currents. The wire break detection ensures that a break in the sensor circuit (e.g., in the transformer) is detected and the device responds to prevent false alarms.

Technology Explained Simply
The IL5882.38 operates on the residual current principle, where the output relay is not activated in the event of a fault, but instead the states pre-warning and alarm are indicated by LED displays (red). The green LED indicates the presence of auxiliary voltage. The differential current measurement is performed via an external differential current transformer, which encloses all conductors of the circuit to be monitored (excluding PE). In a fault-free state, the sum of all currents is zero, so no voltage is induced in the transformer. In the event of an insulation fault, a fault current flows to earth, creating a current difference that is detected by the transformer and evaluated by the IL5882. The response time is short, with a default time delay of 5 seconds.

Compatibility and Accessories
The device is designed for connection to external differential current transformers such as the ND 5016, ND 5019, or the hinged current transformer ND 5014. These transformers are connected via terminals i and k. The IL 5882 housing type is intended for installation distributors with bottom-mounted terminals and a depth of 63 mm. The device class Type A allows monitoring of alternating and pulsating direct currents according to IEC/TR 60755. The UKCA and CCC certifications confirm compliance with applicable standards.

Mounting and Installation
Mounting is performed in installation or industrial distributors according to DIN 43880. The width is 35 mm, and the depth is 63 mm. The connection terminals are located at the bottom. Installation requires connection to an external differential current transformer, which encloses all conductors of the circuit to be monitored (excluding PE). The auxiliary voltage is connected via terminals A1/A2. The test and reset button allows for functional testing and resetting the device after an alarm.

Advantages in Operation
The IL5882.38 provides preventive protection against fires and equipment damage through early detection of insulation faults. High system availability is ensured by the option for pre-warning and continuous monitoring without operational interruption. The sealable transparent cover protects the adjustment switches from unauthorized changes. The LED indicators enable quick visual status monitoring. The alarm value storage is optional, allowing documentation of fault history. The frequency range coverage from 20 to 2000 Hz makes the device suitable for a wide range of applications.