Further information for Dold 0054589 BH5928.47 AC/DC24V 1-10S safety relay
Technical data
1- / 2-channel
1, 2
Approvals
UL
Cat. / PL acc. to EN ISO 13849-1
4/e
Connection
Pluggable screw terminals
Output contacts max.
3 NO contacts, 3 NO contacts delayed
SIL CL acc. to IEC/EN 62061
3
SIL acc. to IEC/EN 62061
3
Thermal current Ith max.
5 A
Width
45 mm
Type
BH 5928
Cross fault detection
Suited as safety gate monitor
Variant
Contact equipping
3 NO contacts, 1 NC contact instantaneous, 1 NO contact off delay
Nominal voltage
AC/DC 24 V
Time range
1 - 10 s
Approvals and Markings
UL-listed C/US, TÜV, CCC
Variant
With adjustable time delay
The Dold safety relay BH5928.47 AC/DC24V 1-10S is an emergency stop module for use in industrial safety systems. It serves the protective function for personnel and machinery, particularly in systems with emergency stop circuits that must meet Stop Category 1 requirements. The device is specifically designed for monitoring sliding safety grilles and enables reliable machine shutdown in emergency situations. The width is 45 mm, allowing compact mounting in standard control panels.
Applications
The safety relay is used in systems where safe shutdown is required in case of danger. Typical applications include machines with moving parts, where an emergency stop button or safety door must be monitored. Its function as a safety door monitor makes it suitable for systems where access to hazardous areas is controlled by mechanical safety grilles. Integration into emergency stop circuits enables the realization of Stop Category 1 according to EN ISO 13849-1, ensuring immediate and safe machine shutdown.
Functions and equipment in detail
The device features contact configuration with 3 NO contacts, 1 NC contact immediately, and 1 NO contact with delayed reset. The delayed reset function enables controlled shutdown, where the machine is switched off not immediately after triggering the emergency stop button, but within a time range of 1 to 10 seconds. This is particularly useful to reduce mechanical stress or to ensure all movements have completed. Connection technology uses removable screw terminals, enabling flexible and secure wiring. The terminals are designed for conductor cross-sections of 2 x 1.5 mm² stranded wire with sleeve and plastic collar DIN 46 228-1/-2/-3/-4 or 2 x 2.5 mm² stranded wire with sleeve DIN 46 228-1/-2/-3.
Technology explained clearly
The safety relay operates at a nominal voltage of AC/DC 24 V and is suitable for 1- or 2-channel wiring. The 2-channel variant increases safety, as both channels are monitored independently. Cross-connection detection at the single-button (terminals S33–S34) detects faults in the control circuit, for example, short circuits. The status indicator for the delayed reset timing circuit and LED indicators for power supply, channel 1/2, and timing delay enable visual monitoring of the operating status. The choice between manual activation via the single-button or automatic activation with bridge at S13–S14 offers flexibility when integrating into existing systems.
Compatibility and accessories
The device is equipped with adjustable time delay, allowing the delay time to be set between 1 and 10 seconds. Certifications include UL-listed C/US, TÜV, and CCC, enabling use in various markets. The safety functions comply with standards EN ISO 13849-1 (Category 4, Performance Level e) and IEC/EN 62061 (SIL CL 3, SIL 3), ensuring reliability and safety in critical applications. The thermal current rating is up to 5 A, sufficient for most industrial applications.
Mounting and installation
Mounting is in standard control panels with a width of 45 mm. The removable screw terminals facilitate installation and maintenance. Wiring is carried out according to the circuit diagrams in the datasheet, with terminal assignments and functions of individual connections clearly defined. The status indicators and LED displays support commissioning and fault diagnosis.
Advantages in operation
The safety relay offers high reliability through integrated cross-connection detection and redundant 2-channel wiring. The adjustable time delay allows application-specific adaptation, while the LED indicators visually monitor the operating status. Certifications according to international standards ensure suitability for use in various industries and regions. The compact design and flexible connection technology facilitate integration into existing systems.