Further information for Dold 0054581 BL5903.03/00020 AC230V safety relay
Technical data
1- / 2-channel
1, 2
Cat. / PL acc. to EN ISO 13849-1
4/e
Connection
Pluggable screw terminals
Output contacts max.
3 NO contacts
SIL CL acc. to IEC/EN 62061
3
SIL acc. to IEC/EN 62061
3
Thermal current Ith max.
5 A
Width
90 mm
Type
BL 5903
Cross fault detection
Variant
Contact equipping
3 NO contacts
Nominal voltage
AC 230 V
Approvals and Markings
TÜV, UKCA
Variant
Für 1-kanaligen Anschluß von zwei Not-Aus-Tastern
The Dold safety relay BL5903.03/00020 AC230V is a specialised emergency stop module for industrial applications where safe shutdown and controlled restart after power failure are required. The device is designed for use in systems such as compressor controls, water and wastewater technology, where the reliability of the emergency stop function and the return to operation after power restoration are critical. It features a 1-channel configuration designed for connecting two emergency stop pushbuttons, enabling redundant safety monitoring. The rated voltage is AC 230 V, and the device is equipped with removable screw terminals to ensure flexible and secure wiring.
Applications
The safety relay BL5903 is used in industrial control systems where protection against unwanted restarts after a power failure is required. It is particularly suitable for systems that should automatically resume operation after a power failure, provided no emergency stop has been activated. The power failure detection function ensures that operation is only resumed when voltage is restored and no emergency stop activation is present. This protects personnel and machinery from dangerous, uncontrolled restarts.
Functions and Equipment in Detail
The device stores the activation of an emergency stop pushbutton and accordingly activates the output contacts. The output contact configuration includes 3 NO contacts, which can be used to control auxiliary contacts or safety relays within the system. The cross-circuit detection monitors the input lines and detects faults such as short circuits or wire breaks, ensuring the integrity of the safety function. Additionally, the module features a feedback loop, enabling external contact amplification to support signal transmission in complex systems.
Technology Explained Simply
The safety functions of the BL5903 are based on internationally recognised standards. It complies with Performance Level (PL) e and Category 4 according to EN ISO 13849-1, representing the highest requirement for safety functions in industrial systems. Furthermore, it meets the requirements for SIL 3 (Safety Integrity Level) according to IEC/EN 62061 and IEC/EN 61508, confirming the reliability and fault tolerance of the device in safety-critical applications. The LED indicators for Channel 1 and 2, as well as for fault diagnosis, allow for quick visual inspection of the operating status and support maintenance. The removable terminal blocks simplify installation and maintenance, as they can be removed and repositioned without tools.
Compatibility and Accessories
The module is designed for use in systems requiring a 1-channel safety function with two emergency stop pushbuttons. It is compatible with standard wiring, supporting connection cross-sections up to 2 x 2.5 mm² stranded wire with sleeve DIN 46228-1/-2/-3 or 2 x 1.5 mm² stranded wire with sleeve and plastic collar DIN 46228-1/-2/-3/-4. The width is 90 mm, making it suitable for standard control panels. The TÜV and UKCA certifications confirm compliance with European and British safety standards.
Mounting and Installation
Mounting is carried out in standard control panels with a width of 90 mm. The removable screw terminals allow for easy and secure wiring. The connection terminals are designed for use with stranded wire and sleeves according to DIN 46228, ensuring a standardised and secure connection. The LED indicators support installation by directly displaying the operating status and potential faults.
Operational Advantages
The BL5903 offers high safety integrity through the combination of PL e, Category 4, and SIL 3. The automatic restart function after power failure reduces operational interruptions without compromising safety. Cross-circuit detection, as well as wire break and short-circuit detection, increase system reliability. Visual fault diagnosis via LED indicators simplifies maintenance and reduces error rates during inspections. The 90 mm width and use of removable terminals make the device flexible for use in various industrial environments.