Further information for Dold 0053945 load monitor AC230/110V
Technical data
1- / 3-phase
1, 3
Enclosure design
Switch cabinet
Measuring range max.
40 A (37 kW)
Output contacts
2 x 1 C/O contacts
Width
45 mm
Type
BH 9097
Operate delay
Variant
Auxiliary voltage
AC 230/110 V
Contact equipping
2 x 1 changeover contact
Nominal current max
AC 24 A
Nominal voltage
AC 35 - 250 V
Approvals and Markings
CCC
Variant
1-phase with auxiliary supply. Start up delay time 0 - 30 s
The load monitor BH9097.38/010AC30-240VAC230/110V from Dold is an industrial monitoring switch of the VARIMETER series, used for continuous monitoring of the electrical load of motors and other electrical consumers in industrial installations. The device detects deviations from pre-set load limits and responds by activating output relays to provide early warning of impending faults or failures. The operation is based on active power measurement, where the load is set in absolute values in watts using rotary switches. The device is intended for use in enclosures and has a width of 45 mm, allowing integration into standard switchboards.
Applications
The load monitor is specifically designed for monitoring electrical industrial drives with variable motor loads. It is suitable for motors up to 22 kW at 400 V or up to 37 kW at 690 V. Measurement is performed according to the single-phase principle, assuming symmetrical loading of all three phases, which is typical for motor loads. The device can be used for both single-phase and three-phase installations, with configuration done via DIP switches. Monitoring occurs in two stages: underload (P1) and overload (P2), with the setting switchable between underload/overload monitoring and overload monitoring with a pre-warning stage (P1max/P2max).
Functions and Equipment in Detail
The device features two independent output relays, each with a 1 changeover contact, for signaling P1 and P2. The relays can be configured for either active current operation (activated in fault condition) or passive current operation (not activated in fault condition), with selection done via DIP switches. A common start-up bypass time ta (0–30 s) prevents false alarms during motor start-up. Settings are adjusted using rotary switches on an absolute scale in watts. A test/reset button facilitates commissioning and serves as an adjustment aid.
Technology Explained Simply
Measurement is performed via active power, with the device capable of measuring up to 40 A without an external current transformer. Automatic range switching enables a wide measurement range. The auxiliary voltage is AC 230/110 V, while the rated voltage of the device is AC 35–250 V. The maximum rated current is AC 24 A. The output relays are coupled with LEDs indicating the switching state: the green LED indicates mains voltage, while the yellow LEDs for P1 and P2 indicate operating status (steady light) or the delay time (flashing). In case of faults, such as missing measurement voltage or reverse power, all LEDs flash in specific patterns to indicate the fault cause.
Compatibility and Accessories
The device is designed for use in industrial enclosures and complies with the standard IEC/EN 60255-1. It is suitable for single-phase and three-phase installations. Configuration is done via DIP switches, which determine the operating mode (underload/overload or overload with pre-warning stage) and memory behavior (automatic or manual). The connection terminals are designed for connecting to loads and auxiliary voltage.
Mounting and Installation
Mounting is done in standard switchboards with a width of 45 mm. Connections are clearly labeled, enabling easy wiring. Load limit settings are adjusted using rotary switches, with values indicated in watts. The start-up bypass time and response delay are set via DIP switches. LED indicators support commissioning and fault diagnosis.
Advantages in Operation
By enabling early detection of load deviations, the load monitor allows for preventive maintenance and prevents costly damage. Reduced wiring effort and clear LED signaling facilitate integration into existing installations. The device’s configurability for various operating modes increases application flexibility. Reliable monitoring and clear fault indication contribute to operational safety and high system availability.