Technical data
Load current up to
40 A
Load voltage up to
AC 400 V
Number of poles
1-pole
On/Off Input Control
AC/DC
Width
45 mm, 67,5 mm, 112,5 mm
Type
BH 9251
Signalling output
Temperature monitoring
Variant
Contact equipping
1 changeover contact
Load current
10 A
Nominal voltage
AC 48 V
The Dold semiconductor contactor BH9251.11 AC48V 50/60HZ 10A is an electronic switching device for controlling and monitoring single-phase AC loads in industrial applications. It is particularly designed for switching and monitoring up to 12 parallel-connected heating elements in machines such as packaging systems, plastic injection moulding machines, or blister packaging machines. The device operates on the principle of zero-voltage switching to minimise switching sparks and voltage surges, and is designed for continuous operation. The rated voltage is AC 48 V, with the control input X1-X2 being galvanically isolated and supporting a voltage range of AC/DC 9.6 to 270 V. Control is performed digitally via an impulse with a minimum duration of ≥ 100 ms.
Applications
This semiconductor contactor is designed for use in industrial machines where precise and reliable control of heating loads is required. It is particularly suitable for applications where high availability and safety of heating systems must be ensured, such as in the packaging industry or plastic processing machines. The maximum load voltage is AC 400 V, and the load current can reach up to 40 A, with the specified variant rated for 10 A. At a load voltage of AC 230 V, the total power of the connected heating elements can reach up to 2300 W, with each individual heating element having a power of 190 W.
Functions and Features in Detail
The device includes integrated current monitoring, detecting undercurrent, overcurrent, and interruptions in the load circuit. Temperature monitoring protects the power semiconductor from overheating. In the event of a fault, the output relay is not activated (standby current principle), ensuring safe disconnection. A signalling relay with 1 changeover contact serves as an output for indicating faults to an external system. The current pickup threshold is adjustable continuously within the measurement range, with fixed pickup thresholds for overcurrent (≥ 10 % of the end value of the measurement range) and undercurrent (-8 % of the end value of the measurement range). The evaluation time is ≤ 100 ms, enabling rapid response to load changes.
Technology Explained Simply
The semiconductor contactor is based on power electronics, cooled thermally via an integrated heatsink. Switching is performed using semiconductors, eliminating mechanical contacts and increasing service life. The galvanic isolation of the control input ensures high safety and prevents interference between the control and load circuits. Compensation for voltage fluctuations of ± 20 % ensures stable operation even with irregular mains voltage. LED indicators signal the operating status: a green LED remains lit continuously when mains voltage is present and the setpoint at the potentiometer matches the load current.
Compatibility and Accessories
The device is designed for use with single-phase AC loads up to 400 V and is available in various widths (45 mm, 67.5 mm, 112.5 mm). The width of the variant described here is 45 mm. It is snap-mounted onto a DIN rail, enabling easy installation in enclosures. Compliance with IEC/EN 60947-1 and IEC/EN 60947-4-2 ensures adherence to industrial safety standards. The maximum operating temperature is 40 °C, with a current reduction of 0.2 A per °C above this temperature. The maximum ambient temperature is 60 °C, at which the device remains operational, albeit with reduced load capacity.
Mounting and Installation
Mounting is done by snapping onto a DIN rail, enabling quick and secure installation in enclosures. Connections for load and control are clearly labelled, with the control input X1-X2 being galvanically isolated. The load terminals (11, 12, 14) are intended for connection to the load to be switched. Power supply is via mains voltage (AC 48 V), with no auxiliary voltage required. Installation is to be carried out in a closed enclosure, with the operating altitude to be below 2000 m.
Operational Advantages
The semiconductor contactor offers high reliability through integrated current and temperature monitoring. Galvanic isolation and zero-voltage switching enhance safety and reduce electromagnetic interference. The long mechanical service life of ≥ 10⁶ switching operations and electrical service life of 2 × 10⁵ switching operations at 3 A/AC 230 V make the device suitable for long-term industrial applications. Easy mounting on DIN rail and clear LED indication facilitate maintenance and diagnostics during operation. Integrated cooling and current reduction at elevated temperatures ensure stable operation even under challenging environmental conditions.