Further information for Dold 0053714 voltage relay AC25-250V
Technical data
1- / 3-phase
1
Enclosure design
Switch cabinet
Nominal voltage max.
AC 1000 V, DC 900 V
Output contacts
2 C/O contacts
Width
45 mm
Type
BA 9054
Operate delay
Variant
Auxiliary voltage
AC/DC 80 - 230 V
Contact equipping
2 changeover contacts
Measuring range
AC 25 - 250 V
Start up delay
Without
Switching delay
0 - 20 s
Approvals and Markings
UKCA, CCC
Variant
Undervoltage relay. De-energized on trip. Time delay at hysteresis value
The voltage relay BA9054/012 from Dold is an undervoltage relay for monitoring single-phase DC and AC power networks. It operates on the standby current principle, where the contacts are closed during normal operation and open when the set threshold value is undershot. Device setting is performed via rotary switches on the front side, enabling simple and user-friendly configuration. The relay is designed for use in industrial and railway applications, where reliable voltage monitoring is crucial to prevent failures and ensure operational safety.
Applications
The BA9054/012 is used to continuously monitor voltage in electrical installations. It serves for early detection of voltage dips that could cause damage to connected devices. The application takes place in enclosures, where the device is mounted in standard 45 mm width. It is particularly suitable for systems requiring preventive maintenance and rapid fault localization to increase productivity and minimize downtime.
Functions and Equipment in Detail
The relay features 2 changeover contacts as output contacts, which can be used to control auxiliary circuits or alarm systems. The switching delay is 0 to 20 seconds and is activated when the hysteresis value is undershot, enabling a delayed response to short-term voltage dips. The auxiliary voltage is supplied in the range of AC/DC 80 to 230 V, ensuring flexible integration into existing power supply systems. The measurement range coverage is AC 25 to 250 V, with devices calibrated for sinusoidal AC voltages in RMS value. Measurement is performed via the arithmetic mean of the rectified measured voltage.
Technology Explained Simply
The galvanic isolation between auxiliary circuit and measurement circuit ensures high safety and prevents disturbances in the measurement circuit caused by disturbances in the auxiliary circuit. The LED indicators signal the operating status: a green LED lights up when operating voltage is applied, a yellow LED when the output relay is activated. The response delay is integrated to filter short-term voltage fluctuations and avoid false triggers. The rated voltage max. is AC 1000 V and DC 900 V, ensuring high load capacity and operational safety in industrial environments.
Compatibility and Accessories
The relay is compliant with IEC/EN 60255-1 and IEC/EN 60947-1 standards and carries the approvals UKCA and CCC. It is designed for use in enclosures and can be integrated into existing control systems. The connection terminals are clearly labeled: A1/A2 for auxiliary voltage, e/f for measurement voltage input, and contacts 11-14 and 21-24 for the two changeover contacts.
Mounting and Installation
Mounting is performed in an enclosure, with the 45 mm width ensuring compatibility with standard control panels. The connection terminals are designed for secure connections, and adjustment is done via rotary switches on the front side.
Operational Advantages
The BA9054/012 provides precise and reliable voltage monitoring, contributing to the prevention of device damage due to overvoltage. The integrated switching delay enables differentiated response to voltage fluctuations, reducing the number of false triggers. The LED indicators facilitate visual monitoring of the operating status. Galvanic isolation increases system safety and reliability. Compliance with standards and approvals ensures adherence to applicable safety regulations.