Dold 0053546, EAN: 4030641535469

Dold 0053546 IP5924.04 AC110V 50/60Hz emergency stop module

Dold 0053546 IP5924.04 AC110V 50/60Hz emergency stop module

Lieske Part No. 1002000
Mfg Part No 0053546
EAN-Code 4030641535469
Manufacturer Dold
Here only 306,00 EUR
364,14 EUR incl. VAT

Further information for Dold 0053546 IP5924.04 AC110V 50/60Hz emergency stop module

Technical data
1- / 2-channel1, 2
Cat. / PL acc. to EN ISO 13849-14/e
ConnectionPluggable screw terminals
Output contacts max.4 NO contacts
SIL CL acc. to IEC/EN 620613
SIL acc. to IEC/EN 620613
Thermal current Ith max.5 A
Width70 mm
TypeIP 5924
Variant
Contact equipping4 NO contacts
Nominal voltageAC 110 V 50/60 Hz
Approvals and MarkingsTÜV, UKCA
The Dold IP5924.04 AC110V 50/60HZ is an emergency stop module of the IP 5924 series, specifically designed for safety-oriented applications in industry. It serves to protect personnel and machinery by securely enabling and interrupting a safety circuit. The device is designed for use in installations with high safety requirements and meets the requirements for Performance Level (PL) e and Category 4 according to EN ISO 13849-1 as well as Safety Integrity Level (SIL) 3 according to IEC/EN 62061. The width is 70 mm, making it suitable for installation in standard control panels. The rated voltage is AC 110 V at 50/60 Hz, and the contact configuration includes four normally closed contacts (NO). The connection technology uses removable screw terminals, enabling flexible and secure connections.

Applications

The emergency stop module IP 5924 is intended for safety-critical applications in industrial automation, particularly in machine controls, installations with combustion systems (according to EN 50156-1), and in systems requiring manual or automatic start enablement. It is used to safely shut down operations in hazardous situations and to allow restart only after manual confirmation. Compliance with standards EN ISO 13849-1 and IEC/EN 62061 makes it suitable for installations operating in Category 4 (PL e) or SIL 3.

Functions and Equipment in Detail

The module features an LED indicator for operational status as well as for Channel 1 and Channel 2, enabling visual monitoring of the operational state. A short-circuit detection between terminal Y1 and ground provides additional safety by detecting unauthorized electrical connections. The contact configuration with four normally closed contacts allows parallel control of multiple loads or safety functions. The maximum thermal current rating (Ith) is 5 A, defining the contact load capacity. The TÜV and UKCA certifications confirm compliance with European and British safety standards.

Technology Explained Simply

The safety function of the module is based on interrupting a safety circuit when the emergency stop is triggered. The contacts are configured as normally closed, meaning they are closed during operation and open when triggered to interrupt power supply. Galvanic isolation in the circuit (in AC 230 V variants) ensures electrical separation between control and load circuits, enhancing safety. The removable screw terminals simplify installation and maintenance, as they can be removed and reinstalled without tools. The width of 70 mm corresponds to the standard for DIN control panels, enabling easy integration into existing control systems.

Compatibility and Accessories

The module is available in single-channel and dual-channel versions, with the dual-channel variant enabling redundant safety functions. It is compatible with other components of the BG 5924 and IP 5924 series, particularly with removable terminal blocks. The connection cross-sections are designed for wires up to 2.5 mm², with the use of ferrules and plastic collars according to DIN 46228-1/-2/-3/-4 recommended. Wires with 1.5 mm² cross-section can also be used if appropriate ferrules and collars are applied.

Mounting and Installation

Mounting is performed in standard control panels with DIN rail. The removable terminal blocks can be removed without tools, simplifying installation and maintenance. The connection terminals are designed for wire connections, with maximum cross-sections and the use of ferrules and collars according to DIN 46228-1/-2/-3/-4 required. Adherence to mounting instructions is essential for the functional safety of the module.

Operational Advantages

The combination of high safety level (PL e / Cat. 4, SIL 3), visual status indication, and short-circuit detection ensures a reliable and monitorable safety function. The removable terminal blocks and standard width of 70 mm facilitate integration into existing installations. Compliance with standards EN ISO 13849-1 and IEC/EN 62061 ensures conformity with international safety standards, which is important for machine and installation certification. The LED indicators enable quick diagnosis of operational status, accelerating maintenance and troubleshooting.
This is an offer of:

Lieske Elektronik e.K.

Reutener Str. 10
79279 Vörstetten

https://industry-electronics.com
Tel. 07666/88499-0
Fax. 07666/88499-111

Diesen Artikel finden Sie unter:
industry-electronics.com/artikel/1002000
qrcode für Dold 0053546 IP5924.04 AC110V 50/60Hz emergency stop module