| Technical data |
| 1- / 2-channel | 1, 2 |
| Cat. / PL acc. to EN ISO 13849-1 | 4/e |
| Connection | Pluggable screw terminals |
| Output contacts max. | 4 NO contacts |
| SIL CL acc. to IEC/EN 62061 | 3 |
| SIL acc. to IEC/EN 62061 | 3 |
| Thermal current Ith max. | 5 A |
| Width | 70 mm |
| Type | IP 5924 |
| Variant |
| Contact equipping | 2 NO contacts |
| Nominal voltage | AC/DC 48 V |
| Approvals and Markings | TÜV, UKCA |
The Dold IP5924.02 AC/DC48V is an
emergency stop module of the IP 5924 series, specifically developed for safety-oriented applications in industrial environments. It is designed for the safe release and interruption of safety circuits to protect personnel and machinery from hazards. The device is designed for use in systems with high safety requirements and complies with standards for safety functions up to Performance Level (PL) e and Category 4 according to EN ISO 13849-1 as well as Safety Integrity Level (SIL) 3 according to IEC/EN 62061. The TÜV and UKCA certifications confirm compliance with European safety standards.
Applications
This module is used in industrial safety systems, particularly in systems certified according to EN 50156-1 for combustion systems. It is suitable for applications where safe shutdown is required in hazardous situations, for example in manufacturing industry, machines with moving parts, or systems with potential fire or explosion hazards. The 1- or 2-channel wiring allows flexible integration into existing safety architectures.
Functions and equipment in detail
The device features
2 normally closed contacts as contact configuration and can support up to
4 normally closed contacts as output contacts. The rated voltage is
AC/DC 48 V, making it suitable for a wide range of industrial power supplies. The connection technology uses
removable screw terminals, enabling flexible and secure connections. The terminal blocks can be used for wires up to 2.5 mm² with ferrules according to DIN 46228-1/-2/-3/-4. The width is
70 mm, allowing installation in standard control panels.
Technology explained simply
The module operates based on the principle of safe signal processing. In the event of an emergency stop, the safety circuit is interrupted to safely shut down the machine or system. Functions such as
short-circuit detection between terminal Y1 and ground increase the system's reliability. The integrated
LED indicators for channel 1 / 2 and operating status allow visual monitoring of the module during operation. The thermal loading is defined by a maximum thermal current
Ith max. of 5 A, describing the electrical loading under continuous operation.
Compatibility and accessories
The module is designed for use in systems with
1- or 2-channel wiring. It is compatible with other components of the IP 5924 and BG 5924 series, especially in combination with emergency stop switches or other safety modules. Galvanic isolation in the circuit (for AC 230 V variants) is not specified for this AC/DC 48 V variant; however, the safety function is guaranteed regardless of voltage type.
Mounting and installation
Mounting is done in standard control panels with a width of 70 mm. The removable terminal blocks facilitate installation and maintenance. The connection terminals are designed for wires up to 2.5 mm², with the use of ferrules according to DIN 46228-1/-2/-3/-4 recommended. Installation requires no additional tools, as the terminal blocks are inserted directly into the control panel.
Advantages in operation
The module offers high safety integrity with SIL 3 and PL e, which is required for critical applications. The LED indicators enable quick diagnosis during operation. The removable terminal blocks simplify maintenance and replacement. Compliance with TÜV and UKCA, as well as certification according to EN 50156-1 for combustion systems, increases acceptance in various industries. The thermal loading of 5 A ensures reliable operation under continuous load conditions.