Further information for Dold 0053404 semiconductor contactor 3xAC 5A
Technical data
Approvals
UL
Load current up to
50 A
Load voltage up to
AC 480 V
Number of poles
1-pole, 2-pole, 3-pole
On/Off Input Control
DC
Width
45 mm, 67,5 mm, 112,5 mm
Type
BH 9250
Signalling output
Temperature monitoring
Variant
Auxiliary voltage
DC 24 V
Contact equipping
with signal contact
Load current
3 x AC 5 A
Load voltage
AC 24 - 480 V
Semiconductor output
3-pole
Approvals and Markings
UL-listed C/US
Variant
Switching at zero crossing. Control input X1 with low current consumption. Monitoring output for the temperature protection
The Dold semiconductor contactor BH9250.03/001 UH=DC24V 3xAC 5A is an electronic switching device for use in industrial systems, designed for noiseless and frequent switching of loads such as heaters, motors, valves, and lighting. It is a semiconductor contactor with 3-pole configuration, operated by an auxiliary voltage of DC 24 V, and capable of switching loads in the voltage range of AC 24 to 480 V with a load current of 3 x AC 5 A. The device is manufactured in accordance with the standards IEC/EN 60947-4-2 and IEC/EN 60947-4-3 and meets the requirements for electronic contactors in industrial applications.
Applications
This contactor is intended for use in industrial control and automation systems, particularly in applications requiring noiseless and wear-free switching. It is suitable for applications involving frequent switching operations, such as in conveyor systems, air conditioning systems, pump controls, or lighting installations. The zero-voltage switching ensures that the switching operation occurs at the moment of zero crossing of the alternating voltage, minimizing inrush currents and extending the service life of both the load and the contactor.
Functions and Features in Detail
The device features a control input X1 with low current consumption, enabling it to be controlled via a PLC (Programmable Logic Controller) or other digital control devices. The temperature monitoring of the power semiconductors protects the device from overheating and extends its service life. When a critical temperature is reached, an alarm output is activated, which can signal a fault through an external circuit or control system. The integrated protection circuitry using varistors provides additional protection against overvoltages and transient voltage spikes.
Technology Explained Simply
The semiconductor contactor operates without mechanical contacts, instead using semiconductor components such as thyristors or triacs to switch the load. This enables wear-free and noiseless switching, which is particularly advantageous for frequent switching operations. The zero-voltage switching ensures that the switching operation occurs at the moment of zero crossing of the alternating voltage, minimizing inrush currents and extending the service life of both the load and the contactor. The temperature monitoring monitors the heat generation of the semiconductors and disconnects the output if a critical temperature is exceeded, preventing damage.
Compatibility and Accessories
The device is designed for use in systems with AC loads up to 480 V and load currents up to 50 A. It is available in various configurations, including 1-pole, 2-pole, and 3-pole variants, with widths depending on the model of 45 mm, 67.5 mm, or 112.5 mm. The snap-on mounting on DIN rail allows for easy and standardized installation in enclosures. The UL-listed C/US certification confirms suitability for use in the USA and Canada.
Mounting and Installation
The contactor is mounted on a DIN rail, with the width varying depending on the model. The terminal connections are clearly labeled: A1/A2 serve as control or operating voltage, X1 is the additional control input, L1/L2/L3 are the mains connections, and T1/T2/T3 are the load outputs. The alarm output is available via terminal 18. Installation must follow the manufacturer’s technical instructions, ensuring correct wiring and compliance with electrical standards.
Operational Advantages
The semiconductor contactor offers high efficiency, as it operates without mechanical contacts and therefore exhibits no wear. The zero-voltage switching reduces inrush currents and extends the service life of the loads. The temperature monitoring with alarm output enables early fault detection and prevents damage due to overheating. The low current consumption at control input X1 makes it particularly suitable for control via PLC systems. The UL certification ensures suitability for use in the USA and Canada.