Further information for Dold 0053382 IL5880.12/200 DC24V insulation monitor 5-100k
Technical data
Enclosure design
Distribution board
IMD type
AC
Nominal voltage IT system
AC 0 - 500 V
Response value
5 - 500 kΩ
Response value type
Adjustable
Width
35 mm
Type
IL 5880
Earth fault indicator
Variant
Alarm value
5 - 100 kOhm
Auxiliary voltage
DC 24 V
Contact equipping
2 x 1 changeover contact
Prewarning value
10 kOhm - 5 MOhm
Approvals and Markings
UKCA, CCC
Variant
Adjustable alarm and pre-warning value. Programmable outputs. De-energized on trip
The insulation monitor IL5880.12/200 DC24V from Dold is a device for monitoring insulation resistance in ungrounded pure alternating and direct current networks (IT systems) with a nominal voltage of AC 0 to 500 V. The device operates on the idle current principle, in which the output relays are not activated in the event of a fault, ensuring a safe and reliable response in the event of an earth fault. The auxiliary voltage is DC 24 V, enabling monitoring of de-energized systems as well. The width is 35 mm, and the device is designed for mounting in installation and industrial distributors according to DIN 43880. The housing design is configured as an installation distributor, with connection terminals located at the bottom.
Applications
The insulation monitor is intended for pure alternating and direct voltage networks in the frequency range of 10 to 10000 Hz. It is particularly suitable for applications in industry, railway operations, and mobile power generators, with the variant IL/SL 5880/300 complying with DIN VDE 0100-551 specifically available for mobile power generation systems. Monitoring is also possible with de-energized consumers, for example, motor windings of devices that must be switched on in an emergency.
Functions and equipment in detail
The device features an adjustable alarm threshold in the range of 5 to 100 kΩ, as well as an additional adjustable pre-warning threshold from 10 kΩ to 5 MΩ. Adjustment is user-friendly via a potentiometer on the front of the device. The function of the output relays is programmable, allowing selection between memory and hysteresis behavior. The hysteresis function is activated when terminals LT1 and LT2 are bridged; if not bridged, memory behavior is applied. The operational status is indicated by LEDs: a green LED indicates operational readiness, a red LED signals an insulation fault (earth fault), and a yellow LED lights up when the pre-warning threshold is undershot.
Technology explained clearly
Insulation resistance measurement is performed by continuously monitoring the resistance between the IT system and earth. When the set alarm threshold is undershot, a signal is sent to the output relays, which, depending on programming, either enter a memory state or trigger hysteresis. Galvanic isolation between the measurement circuit, auxiliary voltage, and output contacts ensures high safety. The output configuration includes two 1-changeover contacts, which can be used to control alarm signals or switching operations. Terminals LT1 and LT2 allow connection of external reset and test buttons.
Compatibility and accessories
The device is specified according to IEC/EN 61557-8 and meets the requirements for monitoring IT systems. It is available in various housing forms, with the variant IL 5880/200 intended for installation distributors. Mounting is either via DIN rail or screws. Additionally, external reset and test buttons can be connected to facilitate operation during use.
Mounting and installation
Mounting is performed in standard installation distributors with a width of 35 mm. The connection terminals are arranged at the bottom, enabling easy integration into existing switchgear. The auxiliary voltage is supplied via terminals A1 (+) and A2 (–). Terminals L and PE are used to connect to the IT system to be monitored and the protective conductor. The functions for memory or hysteresis behavior are configured via terminals LT1 and LT2.
Advantages in operation
The insulation monitor provides preventive fire and system protection through early detection of insulation faults. The adjustable alarm and pre-warning thresholds allow application-specific adaptation. The LED indicators provide clear visual feedback on the operational status. Galvanic isolation and the idle current principle enhance safety during operation. The programmability of the output relays enables flexible integration into existing alarm systems.
Approvals and markings
The device carries the UKCA and CCC approvals, confirming compliance with applicable safety and quality standards.