Further information for Dold 0053380 insulation monitor 220-240V
Technical data
Enclosure design
Distribution board
IMD type
AC
Nominal voltage IT system
AC 0 - 500 V
Response value
5 - 500 kΩ
Response value type
Adjustable
Width
35 mm
Type
IL 5880
Earth fault indicator
Variant
Alarm value
5 - 100 kOhm
Auxiliary voltage
AC 220 - 240 V 50 - 400 Hz
Contact equipping
2 x 1 changeover contact
Prewarning value
10 kOhm - 5 MOhm
Approvals and Markings
UKCA, CCC
Variant
Adjustable alarm and pre-warning value. Programmable outputs. De-energized on trip
The insulation monitor IL 5880.12/200 from Dold is a device for monitoring the insulation resistance in ungrounded pure alternating and rotating current networks (IT systems) with a nominal voltage of AC 0 to 500 V. The device operates on the idle current principle, whereby the output relays are not activated in the event of a fault, ensuring a safe and reliable response in the event of an earth fault. The auxiliary voltage is AC 220 to 240 V at a frequency of 50 to 400 Hz, enabling monitoring of de-energized systems as well. The width is 35 mm, and the device is designed for mounting in installation and industrial distributors according to DIN 43880.
Applications
The IL 5880.12/200 is suitable for pure alternating and rotating current networks with a frequency of 10 to 10000 Hz. It is particularly used in installations where high operational safety and preventive fire and system protection are required. This includes, for example, mobile power generators, industrial plants, and railway applications. The separate supply voltage allows monitoring of de-energized consumers, such as motor windings, which must be switched on in an emergency.
Functions and equipment in detail
The device features two changeover contacts as output contacts, used for signaling alarm and pre-alarm conditions. The alarm threshold is adjustable and ranges from 5 to 100 kΩ, with a variant also supporting a range of 10 to 500 kΩ. Additionally, an adjustable pre-alarm threshold from 10 kΩ to 5 MΩ is available, enabling early notification when insulation resistance decreases. The function of the output relays is programmable, allowing selection between memory and hysteresis behavior. Indication is provided via LEDs: a green LED indicates operational readiness, a red LED signals an earth fault (alarm), and a yellow LED indicates the pre-alarm condition.
Technology explained simply
The insulation monitor supervises the insulation resistance between the network and earth. When the set alarm threshold is exceeded, a signal is triggered via the output relays. The galvanic isolation between the measurement circuit, auxiliary voltage, and output contacts ensures high safety. The threshold setting is adjusted via a potentiometer on the device front, enabling user-friendly adjustment. The integrated reset and test button allows manual resetting and testing of the device. Additionally, external reset and test buttons can be connected to simplify operation in complex installations.
Compatibility and accessories
The device is compliant with IEC/EN 61557-8 and carries the UKCA and CCC certifications. It is available in various forms, with the IL 5880/200 variant designed for installation distributors with bottom-mounted connection terminals. Mounting is either via DIN rail or screws. The connection terminals are intended for connection to the monitored IT network, the protective conductor, and for external test and reset buttons.
Mounting and installation
Mounting is in standard installation distributors or industrial distributors according to DIN 43880. The depth is 61 mm, and the connection terminals are arranged at the bottom. The device front is equipped with a potentiometer for setting the threshold value and LEDs for operational status, alarm, and pre-alarm.
Advantages in operation
The IL 5880.12/200 provides reliable and early detection of insulation faults, increasing the safety of installations and personnel. The simple adjustment of threshold values and programmable relay functions allow flexible adaptation to different requirements. The integrated LEDs and the option for external operation simplify maintenance and testing of the device. Galvanic isolation and the idle current principle ensure safe and stable operation even under critical operating conditions.