Further information for Dold 0052267 semiconductor contactor AC230V 10A
Technical data
Load current up to
40 A
Load voltage up to
AC 400 V
Number of poles
1-pole
On/Off Input Control
AC/DC
Width
45 mm, 67,5 mm, 112,5 mm
Type
BH 9251
Signalling output
Temperature monitoring
Variant
Contact equipping
1 changeover contact
Load current
10 A
Nominal voltage
AC 230 V
The Dold semiconductor contactor BH9251.11 AC230V 50/60HZ 10A is a semiconductor contactor with integrated current monitoring, specifically designed for use in industrial applications such as packaging machines, plastic injection moulding machines, or blister packaging machines. It is used for switching and monitoring up to 12 parallel-connected heating elements at a load voltage of AC 230 V. The maximum total power of the connected heating elements is 2300 W, with each individual heating element having a power of 190 W. The device is certified according to standards IEC/EN 60947-1 and IEC/EN 60947-4-2 and operates with zero-voltage switching to minimize switching sparks and voltage surges.
Applications
This device is intended for use in industrial machines and systems where precise and reliable control of heating elements is required. It is particularly suitable for applications where current flow monitoring is necessary to detect failures of individual heating elements, under- or over-currents, and interruptions in the load circuit. The integrated temperature monitoring protects the power semiconductor from overheating, extending the device’s service life and enhancing operational safety.
Functions and Equipment in Detail
The semiconductor contactor features an adjustable current pickup value, which can be continuously set within the measurement range of 1 to 10 A. The pickup values for under- and over-current are fixed: under-current is detected at -8 % of the end value of the measurement range, and over-current at ≥ 10 % of the end value. The evaluation time is a maximum of 100 ms, enabling a rapid response to disturbances. Current measurement is performed with a resolution of 1 % of the end value of the measurement range and an adjustment accuracy of ± 2.5 %, ensuring precise monitoring. Compensation for voltage fluctuations of up to ± 20 % ensures stable operation even with irregular supply voltage.
Technology Explained Simply
The device operates as a semiconductor contactor, meaning without mechanical contacts, but using a power semiconductor (e.g. thyristor or triac) to electronically control current flow. This enables high switching speed and long service life, as no mechanical wear occurs. Control is achieved via a galvanically isolated input X1-X2, which accepts a voltage of AC/DC 9.6 to 270 V. The pulse duration must be at least 100 ms to ensure reliable actuation. The device requires no auxiliary voltage, simplifying installation. An integrated heatsink ensures efficient heat dissipation, maintaining stable operating temperature.
Compatibility and Accessories
The device is designed for operation with single-phase AC loads up to 400 V. The load voltage is AC 230 V ± 20 %, and the blocking voltage is 1200 Vp. The maximum load current is 40 A, with the rated load for this model being 10 A. The width is 45 mm, making it suitable for mounting on a DIN rail. The electrical service life is at least 200,000 switching operations at 3 A and AC 230 V, while the mechanical service life is specified as ≥ 1,000,000 switching operations. Short-circuit resistance is ensured by a maximum fuse rating of 4 A gG/gL.
Mounting and Installation
The device is snap-mounted onto a DIN rail, enabling quick and secure installation. Mounting is carried out in an enclosure or control unit. The operating temperature range is 0 °C to +40 °C, with a maximum operating temperature of 60 °C; from 40 °C, current reduction of 0.2 A per degree Celsius applies. The storage temperature is -20 °C to +80 °C, and the operating altitude is limited to below 2000 m.
Operational Advantages
The device offers high operational safety due to integrated current and temperature monitoring. LED indicators signal the operating status: a green LED remains lit continuously when supply voltage is present and the setpoint value matches the actual load current. In the event of a fault, the output relay is not activated (standby current principle), increasing safety. Galvanic isolation of the control input protects against interference and enhances reliability. The integrated cooling and robust construction ensure long service life and low maintenance requirements.
Alarm Output
The device features an alarm output with a changeover contact, which is activated upon detection of a fault (e.g. under- or over-current, interruption). This enables external indication or control, for example via a PLC or warning system. The electrical service life of the alarm output is at least 200,000 switching operations at 3 A and AC 230 V.