Dold 0051271, EAN: 4030641512712

Dold 0051271 safety relay BH5928.47 DC24V 0,5-5S

Industrial Material > Industrial relays and contactors > Safety relay

Dold 0051271 safety relay BH5928.47 DC24V 0,5-5S

Lieske Part No. 217926
Mfg Part No 0051271
EAN-Code 4030641512712
Manufacturer Dold
Here only 507,41 EUR
603,82 EUR incl. VAT

Further information for Dold 0051271 safety relay BH5928.47 DC24V 0,5-5S

Technical data
1- / 2-channel1, 2
ApprovalsUL
Cat. / PL acc. to EN ISO 13849-14/e
ConnectionPluggable screw terminals
Output contacts max.3 NO contacts, 3 NO contacts delayed
SIL CL acc. to IEC/EN 620613
SIL acc. to IEC/EN 620613
Thermal current Ith max.5 A
Width45 mm
TypeBH 5928
Cross fault detectionYes
Suited as safety gate monitorYes
Variant
Contact equipping3 NO contacts, 1 NC contact instantaneous, 1 NO contact off delay
Nominal voltageDC 24 V
Time range0,5 - 5 s
Approvals and MarkingsUL-listed C/US, TÜV, CCC
VariantWith adjustable time delay
The Dold safety relay BH5928.47 DC24V 0,5-5S is a not-out module with integrated time delay, specifically designed for use in safety-critical systems. It serves person and machine protection by implementing emergency stop circuits according to Stop Category 1 and is particularly suitable for monitoring sliding safety grilles. The device is designed for industrial environments and offers an adjustable time delay in the range of 0.5 to 5 seconds, ensuring that machines are switched off in a controlled and safe manner after an emergency stop command. The width is 45 mm, enabling compact mounting in standard control panels.

Applications
This safety relay is used in systems where safe shutdown is required to prevent injuries or damage. Typical applications include machines with moving parts secured by safety doors or grilles, as well as systems requiring immediate shutdown after activation of an emergency stop button. The function as a safety door monitor enables monitoring of access areas, ensuring that the machine can only be started when all safety doors are correctly closed.

Functions and Equipment in Detail
The device features a contact configuration with 3 normally closed contacts, 1 immediate normally open contact, and 1 delayed normally closed contact. The output contacts can include up to 3 immediate normally closed contacts and 3 delayed normally closed contacts, enabling flexible control of various loads. Cross-circuit detection is integrated and can be activated via terminals to detect faults in the emergency stop control circuit. The status indication for the delayed time circuit, along with LED indicators for power supply, channel 1/2, and time delay, supports diagnostics and maintenance. Connection technology is via removable screw terminals, enabling secure and quick wiring. The terminal connections are rated for 2 x 1.5 mm² stranded wire with ferrule and plastic sleeve DIN 46 228-1/-2/-3/-4 or 2 x 2.5 mm² stranded wire with ferrule DIN 46 228-1/-2/-3.

Technology Explained Simply
The time delay of 0.5 to 5 seconds allows for controlled shutdown, which can be adjusted according to application requirements. The adjustable delay ensures that machines are not switched off immediately, but after a defined time, which is necessary for certain processes to avoid damage. The safety functions are designed according to international standards: the device complies with Performance Level (PL) e and Category 4 according to EN ISO 13849-1, representing the highest safety level for safety functions. Additionally, it meets the requirements for SIL 3 according to IEC/EN 62061 and IEC/EN 61508, guaranteeing reliability and fault-free operation under operating conditions. The thermal current rating (Ith max.) is 5 A, indicating the maximum current load for the contacts.

Compatibility and Accessories
The safety relay is suitable for 1- or 2-channel wiring, allowing flexible integration into various safety architectures. Activation occurs either via a single button at terminals S33-S34 or via an automatic single-function with bridge at S13-S14. Certifications include UL-listed C/US, TÜV, and CCC, enabling use in various markets. The LED indicators for power supply, channel 1/2, and time delay support visual monitoring of the operating status.

Mounting and Installation
Mounting is in standard control panels with a width of 45 mm. The removable screw terminals facilitate installation and maintenance. Wiring is carried out according to the circuit diagrams in the datasheet, with terminal assignments and functions of individual connections documented. The status indication and LED indicators enable quick fault diagnosis during commissioning and operation.

Advantages in Operation
The device offers high safety integrity by complying with standards EN ISO 13849-1 and IEC/EN 62061. The cross-circuit detection increases system reliability by detecting faults in the control circuit. The adjustable time delay allows application-specific adaptation, while the LED indicators enable quick status monitoring. The removable terminal blocks facilitate maintenance and replaceability. The certifications UL, TÜV, and CCC guarantee suitability for use in various regions.
This is an offer of:

Lieske Elektronik e.K.

Reutener Str. 10
79279 Vörstetten

https://industry-electronics.com
Tel. 07666/88499-0
Fax. 07666/88499-111

Diesen Artikel finden Sie unter:
industry-electronics.com/artikel/217926
qrcode für Dold 0051271 safety relay BH5928.47 DC24V 0,5-5S