| Technical data |
| 1- / 2-channel | 2 |
| Approvals | UL |
| Cat. / PL acc. to EN ISO 13849-1 | 3/e |
| Classification | For initiators |
| Forcibly guided output contacts max. | 1 NC contact, 2 NO contacts |
| SIL CL acc. to IEC/EN 62061 | 3 |
| SIL acc. to IEC/EN 62061 | 3 |
| Thermal current Ith max. | 4 A |
| Width | 45 mm |
| Type | BH 5932 |
| Variant |
| Contact equipping | 2 NO contacts, 1 NC contact |
| Nominal voltage | AC/DC 24 V |
| Response value | 240 IPM |
| Approvals and Markings | UL-listed C/US, TÜV, CCC |
| Variant | Without sensor detection. NPN-input. Fixed setting value |
The Dold speed monitor BH5932.22/61 AC/DC24V 240IPM is a safety-relevant monitoring switch for speed and standstill monitoring of drives in machines and plants. It is designed to prevent hazards caused by moving machine parts and is intended for use in safety-critical applications. The device features a fixed setpoint of 240 IPM (impulses per minute) and is designed for operation with a nominal voltage of AC/DC 24 V. The width is 45 mm, enabling compact mounting in standard control panels.
Applications
The BH5932 is used in industrial plants where monitoring of rotational and linear movements is required. Typical applications include monitoring motors, conveyor belts, machine tools, or other moving parts, where an unexpected stop or uncontrolled speed could lead to hazards. The device is designed for initiators, i.e., for use with proximity switches that detect motion.
Functions and Equipment in Detail
The device has a 2-channel design, enabling two independent monitoring channels. The contact configuration includes 2 NO contacts and 1 NC contact, with forced-guided contacts to ensure secure signal transmission even in case of faults. The inputs are designed for NPN proximity switches, and this variant does not include initiator connection detection. A feedback circuit (X1–X2) allows monitoring of external contacts, facilitating integration into existing safety concepts.
Technology Explained Simply
The speed monitor detects via connected proximity switches whether a machine is in motion. If the speed drops below the fixed setpoint of 240 IPM, the NC contact is activated, which may trigger the shutdown of the plant. The forced-guided contacts ensure that even in case of an internal fault in the device, the output remains in a defined, safe state. The thermal current rating is up to 4 A, enabling use in plants with corresponding loads. The certifications UL-listed C/US, TÜV, and CCC confirm compliance with international safety standards.
Compatibility and Accessories
The device is compatible with inductive proximity switches from the NA 5001, NA 5002, NA 5005, and NA 5010 series, particularly with types NA 5002.01.34 and NA 5005.01.34, which are intended for devices without initiator connection detection. Connection options are detailed in the datasheet, with wiring via terminals In A / In B. The IP 67 protection rating of the proximity switches makes them suitable for outdoor or damp environments.
Mounting and Installation
Mounting is carried out in standard control panels with a width of 45 mm. The terminal connections are designed for 2 x 1.5 mm² stranded wire with ferrules and plastic collars DIN 46 228-1/-2/-3/-4 or 2 x 2.5 mm² stranded wire with ferrules DIN 46 228-1/-2/-3.
Operational Advantages
The BH5932 offers high safety performance with Category 3 and Performance Level PL e according to EN ISO 13849-1, as well as SIL 3 according to IEC/EN 62061. These certifications enable use in safety-critical plants. The clear structure with a fixed setpoint and forced-guided contacts ensures reliable and predictable response in case of failure. Compatibility with common proximity switches and simple mounting in standard control panels facilitate integration into existing systems.