| Technical data |
| 1- / 2-channel | 1, 2 |
| Approvals | UL-Recognized |
| Cat. / PL acc. to EN ISO 13849-1 | 4/e |
| Connection | Pluggable screw terminals |
| Output contacts max. | 4 NO contacts |
| SIL CL acc. to IEC/EN 62061 | 3 |
| SIL acc. to IEC/EN 62061 | 3 |
| Thermal current Ith max. | 5 A |
| Width | 22,5 mm |
| Type | BG 5924 |
| Variant |
| Contact equipping | 4 NO contacts |
| Nominal voltage | AC 230 V 50/60 Hz |
| Approvals and Markings | TÜV, UKCA, CCC |
The Dold emergency stop module BG5924.04 AC230V 50/60Hz is a safety-oriented switching component for use in industrial systems, particularly for personnel protection and machine protection functions. It is designed for the safe enabling and interruption of a safety circuit and is intended for use in systems complying with safety function requirements according to EN ISO 13849-1 and IEC/EN 62061. The module is available in the version with nominal voltage AC 230 V 50/60 Hz and features a contact configuration with 4 NO contacts. It is suitable for use in single-channel or dual-channel safety applications and is manufactured with a width of 22.5 mm.
Applications
The emergency stop module BG5924.04 is intended for use in safety-critical systems, for example in manufacturing industry, packaging and processing technology, as well as in combustion systems, as it complies with the requirements of EN 50156-1. It is used to safely shut down machine operation in hazardous situations. The function is designed for both manual and automatic start, with safety functions activated independently of the start mode.
Functions and Equipment in Detail
The module features LED indicators that visually display the operating status and the statuses of channels 1 and 2. This enables quick diagnosis during operation. A short-circuit detection between terminal Y1 and ground provides additional safety by detecting potential faults in the connection area. The output contacts are configured as 4 NO contacts, enabling flexible integration into existing safety circuits. Galvanic isolation in the switching circuit ensures high electrical insulation between input and output.
Technology Explained Simply
The safety functions of the module are certified according to standards EN ISO 13849-1 and IEC/EN 62061. It achieves Performance Level (PL) e and Category 4 according to EN ISO 13849-1, representing the highest requirement for safety functions in mechanical systems. Additionally, it meets the requirements for Safety Integrity Level (SIL) 3 according to IEC/EN 62061 and IEC/EN 61508, which is relevant for safety-critical applications in process industry. The thermal current Ith max. is 5 A, indicating the maximum current rating of the contacts. Connection is made via removable screw terminals designed for wire cross-sections up to 2.5 mm², with the option to use ferrules and plastic collars according to DIN 46228-1/-2/-3/-4.
Compatibility and Accessories
The module is designed for use in single- or dual-channel safety systems and can be wired according to the application configuration. It is compatible with other components of the Dold system, particularly with IP 5924 modules, which have a wider mounting width of 70 mm. Certifications TÜV, UKCA, CCC, and UL-Recognized confirm compliance with international safety standards.
Mounting and Installation
Mounting is performed in standard 22.5 mm DIN rail systems, commonly used in industrial electrical engineering. The removable terminal blocks allow for easy and secure wiring. The terminals are rated for wire cross-sections up to 2.5 mm², and the use of ferrules and plastic collars according to DIN 46228-1/-2/-3/-4 is recommended. Mounting requires no additional tools, as the terminal blocks are directly inserted into the DIN rail.
Advantages in Operation
The module provides high safety performance through certification to PL e / Cat. 4 and SIL 3. The LED indicators enable quick status monitoring, and the short-circuit detection increases system reliability. Galvanic isolation in the switching circuit protects against disturbances caused by electrical interference. The use of removable screw terminals simplifies installation and maintenance, thereby extending the operational life of the system. The width of 22.5 mm allows for compact mounting in existing enclosures.