| Technical data |
| 1- / 2-channel | 1, 2 |
| Approvals | UL-Recognized |
| Cat. / PL acc. to EN ISO 13849-1 | 4/e |
| Connection | Pluggable screw terminals |
| Output contacts max. | 4 NO contacts |
| SIL CL acc. to IEC/EN 62061 | 3 |
| SIL acc. to IEC/EN 62061 | 3 |
| Thermal current Ith max. | 5 A |
| Width | 22,5 mm |
| Type | BG 5924 |
| Variant |
| Contact equipping | 2 NO contacts |
| Nominal voltage | AC 230 V 50/60 Hz |
| Approvals and Markings | TÜV, UKCA, CCC |
The Dold safety relay BG5924.02 AC230V 50/60Hz is an emergency stop module for use in safety-critical systems. It is designed for the safe interruption and release of safety circuits to protect personnel and machinery from hazards. The device is designed for industrial applications, particularly in combustion systems, where the standard EN 50156-1 defines requirements for safety functions. The width of 22.5 mm allows for compact mounting in standard control panels.
Applications
This module is intended for applications requiring high safety integrity. It is used to implement safety-oriented functions such as emergency stop, emergency halt, or emergency stop. The certifications TÜV, UKCA, CCC, and UL-Recognized confirm compliance with international safety standards. The module is used in systems certified according to EN ISO 13849-1 and IEC/EN 62061, particularly in installations requiring Performance Level (PL) e and Category 4.
Functions and Features in Detail
The device features two normally open (NO) contacts as output contacts, with up to four NO contacts possible per device. The contact configuration enables safe control of loads during operation. The rated voltage is AC 230 V at 50/60 Hz, with galvanic isolation in the circuit ensuring electrical separation between control and load circuits. LED indicators for Channel 1 and Channel 2, as well as operational status, enable visual monitoring of the module. Short-circuit detection between terminal Y1 and ground provides additional safety.
Technology Explained Simply
The safety function of the BG5924.02 is based on compliance with requirements defined in EN ISO 13849-1 (PL e / Cat. 4) and IEC/EN 62061 (SIL CL 3 / SIL 3). These standards define reliability and safety for controls in critical applications. The module can be used in both single-channel and dual-channel wiring configurations, allowing flexible integration into various safety architectures. The maximum thermal current Ith is 5 A, indicating the maximum current load for the contacts. Connection is made via removable screw terminals suitable for wires with 2 x 1.5 mm² (with ferrule and plastic sleeve DIN 46228-1/-2/-3/-4) or 2 x 2.5 mm² (with ferrule DIN 46228-1/-2/-3).
Compatibility and Accessories
The module is part of the BG 5924 product family and can be combined with other modules in the series to implement complex safety functions. Its use in combustion systems is specifically permitted according to EN 50156-1. It is designed for manual or automatic start, with the exact control logic depending on the specific application. The TÜV, UKCA, CCC, and UL-Recognized certifications ensure compliance with regional and international safety requirements.
Mounting and Installation
Mounting is performed in standard control panels with a width of 22.5 mm. Removable terminal blocks simplify installation and maintenance. The terminals are designed for use with wires according to DIN 46228. Mounting is carried out in the usual manner in control panels, with electrical connections to be made according to the wiring diagrams and technical data provided by the manufacturer.
Operational Advantages
The module offers high safety integrity by meeting the standards PL e / Cat. 4 and SIL 3. The LED indicators allow for quick diagnosis of operational status. Galvanic isolation in the circuit enhances safety against electrical interference. The compact design and flexible wiring options (single- or dual-channel) make the device suitable for a wide range of applications. Short-circuit detection between Y1 and ground prevents potential operational faults.
Safety relay is the product type,
emergency stop module the core function,
PL e / Cat. 4 and
SIL 3 the safety standards,
galvanic isolation the technical feature,
removable screw terminals the connection technology.