Further information for Dold 0050715 safety relay BH5928.92 AC/DC24V 0,5-5S
Technical data
1- / 2-channel
1, 2
Approvals
UL
Cat. / PL acc. to EN ISO 13849-1
4/e
Connection
Pluggable screw terminals
Output contacts max.
3 NO contacts, 3 NO contacts delayed
SIL CL acc. to IEC/EN 62061
3
SIL acc. to IEC/EN 62061
3
Thermal current Ith max.
5 A
Width
45 mm
Type
BH 5928
Cross fault detection
Suited as safety gate monitor
Variant
Contact equipping
2 NO contacts, 1 NC contact instantaneous, 3 NO contacts off delay
Nominal voltage
AC/DC 24 V
Time range
0,5 - 5 s
Approvals and Markings
UL-listed C/US, TÜV, CCC
Variant
With adjustable time delay
The Dold safety relay BH5928.92 AC/DC24V 0,5-5S is an emergency stop module for use in industrial safety systems. It serves the protective function for personnel and machinery, particularly in systems with emergency stop circuits and monitoring of interlock guards. The device is designed for use in 1- or 2-channel safety circuits and offers an adjustable time delay in the range of 0.5 to 5 seconds. The nominal voltage is AC/DC 24 V, making it suitable for use in many industrial control environments. The width of 45 mm allows for compact mounting in standard control panels.
Applications
This safety relay is specifically designed for applications where safe machine shutdown is required, for example, in emergency stop circuits of Stop Category 1. It is also suitable as a safety door monitor to supervise access to hazardous areas. The functions are designed for use in systems with increased safety requirements, particularly in the manufacturing industry, machine tools, or packaging technology.
Functions and Equipment in Detail
The device features contact configuration with 2 NO contacts, 1 NC contact immediately, and 3 NO contacts with delayed reset. The delayed reset contacts enable controlled shutdown, which is necessary for example when stopping drives or switching off tools. The wire break detection at the single-button (connection side at terminals S33–S34) detects faults in the control circuit to prevent unintended shutdown. The status indicator for the delayed reset timing circuit, as well as LED indicators for power supply, channel 1/2, and time delay, support diagnostics and maintenance.
Technology Explained Simply
The safety relay operates according to standards for safety-related control systems. It meets Performance Level (PL) e and Category 4 according to EN ISO 13849-1, indicating high safety performance in hazard avoidance. Additionally, it complies with Safety Integrity Level (SIL) 3 according to IEC/EN 62061, confirming reliability for critical functions. Cross-circuit detection in the emergency stop control circuit can be activated via terminals to detect faults in the control circuit. The maximum thermal current rating is 5 A, enabling use with standard loads. The connection technology uses removable screw terminals, suitable for stranded wires with 2 x 1.5 mm² (with ferrule and plastic sleeve DIN 46 228-1/-2/-3/-4) or 2 x 2.5 mm² (with ferrule DIN 46 228-1/-2/-3).
Compatibility and Accessories
The module is designed for use in 1- or 2-channel safety systems. Activation occurs either via a single-button at terminals S33–S34 or via an automatic single-function with bridge at S13–S14. The connection terminals are removable, facilitating installation and maintenance. Certifications include UL-listed C/US, TÜV, and CCC, enabling use in various markets.
Mounting and Installation
Mounting is done in standard control panels with a width of 45 mm. The removable screw terminals simplify wiring. The connection terminals are clearly labeled to ensure correct wiring. The LED indicators support commissioning and maintenance by visually displaying the operating status.
Advantages in Operation
The safety relay offers high reliability through integrated cross-circuit detection and status indicators. The adjustable time delay allows application-specific adjustment of shutdown time. The combination of immediate and delayed contacts enables flexible control of safety functions. Certifications according to international standards (EN ISO 13849-1, IEC/EN 62061) ensure suitability for safety-critical applications. The connection terminals are suitable for various wire cross-sections, increasing installation flexibility. The LED indicators facilitate diagnostics and maintenance during operation.