Dold 0050369, EAN: 4030641503697

Dold 0050369 BH5928.93 DC24V 0,5-5S safety relay

Industrial Material > Industrial relays and contactors > Safety relay

Dold 0050369 BH5928.93 DC24V 0,5-5S safety relay

Lieske Part No. 1312986
Mfg Part No 0050369
EAN-Code 4030641503697
Manufacturer Dold
Here only 507,41 EUR
603,82 EUR incl. VAT

Further information for Dold 0050369 BH5928.93 DC24V 0,5-5S safety relay

Technical data
1- / 2-channel1, 2
ApprovalsUL
Cat. / PL acc. to EN ISO 13849-14/e
ConnectionPluggable screw terminals
Output contacts max.3 NO contacts, 3 NO contacts delayed
SIL CL acc. to IEC/EN 620613
SIL acc. to IEC/EN 620613
Thermal current Ith max.5 A
Width45 mm
TypeBH 5928
Cross fault detectionYes
Suited as safety gate monitorYes
Variant
Contact equipping3 NO contacts, 3 NO contacts off delay
Nominal voltageDC 24 V
Time range0,5 - 5 s
Approvals and MarkingsUL-listed C/US, TÜV, CCC
VariantWith adjustable time delay
The Dold safety relay BH5928.93 DC24V 0,5-5S is an emergency stop module for use in industrial safety systems. It serves the protective function for personnel and machinery, particularly in systems where a Stop Category 1 must be implemented. The device is suitable for monitoring sliding safety guards and enables a safe shutdown upon actuation of an emergency stop button. The module width is 45 mm, making it suitable for use in standard control panels. The module features an adjustable time delay in the range of 0.5 to 5 seconds, implemented via an integrated timing circuit.

Applications
This safety relay is designed for use in machine controls and systems with enhanced safety requirements. It is particularly used in systems where immediate shutdown is required in case of danger, for example in manufacturing industry, machine building, or packaging technology. The function as a safety door monitor enables monitoring of access protection systems to ensure that machines can only be operated when safety guards are closed.

Functions and Equipment in Detail
The device features contact configuration with 3 normally open contacts (instantaneous contacts) and 3 delayed-closing normally open contacts. The delayed-closing contacts enable controlled shutdown, where output signals are switched off not immediately upon actuation of the emergency stop button, but within an adjustable time range of 0.5 to 5 seconds. This is particularly necessary for systems requiring controlled deceleration or shutdown. The connection technology uses removable screw terminals, enabling flexible and secure wiring. The terminals are designed for conductor cross-sections up to 2.5 mm², and also allow the use of stranded wires with ferrules and plastic collars according to DIN 46 228-1/-2/-3/-4.

Technology Explained Simply
The safety relay operates at a nominal voltage of DC 24 V and is designed for use in 1- or 2-channel circuits. The 2-channel configuration increases safety, as both channels are monitored independently. Cross-connection detection at the single-button input (terminals S33–S34) detects short circuits between buttons, preventing malfunction. Status indicators for the delayed timing circuit, as well as LED indicators for power supply, channel 1/2, and time delay, enable visual monitoring of the operating status. Activation occurs either via a single button at S33–S34 or via an automatic start function activated by a bridge at S13–S14.

Compatibility and Accessories
The module is designed for use in safety systems according to international standards. It complies with Performance Level (PL) e and Category 4 according to EN ISO 13849-1, ensuring high safety performance. The SIL performance limit (SIL CL) 3 according to IEC/EN 62061, as well as classification as SIL 3 according to IEC/EN 61508 and IEC/EN 61511, confirms reliability for critical applications. Certifications include UL-listed C/US, TÜV, and CCC, enabling use in various markets. The device is designed for industrial environments and meets requirements for safety functions in machine controls.

Mounting and Installation
Mounting is performed in standard control panels with a module width of 45 mm. The removable screw terminals facilitate installation and maintenance. Wiring is done via the designated terminals, with the terminal assignment detailed in the manufacturer’s datasheet. Adherence to the specified circuit diagrams and correct wiring are essential for functional safety.

Advantages in Operation
The safety relay offers high reliability through integrated cross-connection detection and redundant 2-channel configuration. The adjustable time delay allows application-specific adaptation, enabling controlled shutdown. LED indicators simplify diagnostics during operation, and the removable terminals support quick maintenance. The device is designed for demanding industrial environments and meets requirements for safety functions in machine controls.
This is an offer of:

Lieske Elektronik e.K.

Reutener Str. 10
79279 Vörstetten

https://industry-electronics.com
Tel. 07666/88499-0
Fax. 07666/88499-111

Diesen Artikel finden Sie unter:
industry-electronics.com/artikel/1312986
qrcode für Dold 0050369 BH5928.93 DC24V 0,5-5S safety relay