Further information for Dold 0050349 IL5990 AC/DC24V 1S surge relay
Technical data
Alarm inputs
4
Alarm inputs extendable up to
160
Enclosure design
Distribution board
Operating principle
De-energized on trip, Energized on trip
Optical signal
LED
Width
35 mm
Type
IL 5990
Optional buzzer
Variant
Contact equipping
2 x 1 NO contact
Nominal voltage
AC/DC 24 V
Operate delay
1 s
The Dold IL5990 AC/DC24V 1S is a fault signal collector for monitoring industrial plants and buildings. It is a fault signal relay with integrated optical indication via LED and a response delay of 1 second. The device is designed according to DIN 19235 and serves for central detection and indication of faults at multiple inputs. It is manufactured in I-form, intended for installation and industrial distributors according to DIN 43880, with a width of 35 mm and a depth of 61 mm. The connection terminals are located at the bottom of the device, facilitating installation in standard distributor boxes.
Applications
It is suitable, for example, for monitoring machines, plants, heating or ventilation systems, where a visual and optionally audible alarm should be triggered in case of a fault. The expandability up to 160 fault signal inputs enables integration into larger systems, with the basic version providing 4 inputs. The inputs are adjustable via bridges X1-X2 to choose between operating current principle (output relay is activated in case of fault) and standby current principle (output relay is not activated in case of fault).
Functions and equipment in detail
The IL5990 features 2 x 1 normally open contacts as contact configuration, with one relay designated for fault signal collection and another for horn alarm. The optical indication is provided by LED indicators showing the status of individual inputs. A front-mounted reset button QH allows manual alarm reset, thereby resetting the LED display. The response delay is standardly 1 second, but can be adjusted to 3 or 10 seconds depending on system requirements to filter out short-term disturbances.
Technology explained clearly
The inputs S1 to S4 are designed for connecting fault sensors or contacts. The power supply is via AC/DC 24 V, with a voltage range between 0.8 and 1.1 times the nominal voltage. The nominal frequency is 50/60 Hz. Fault signals must be present for at least 100 ms to be triggered. Resetting requires an impulse of at least 200 ms. The device is designed for continuous operation and can be used at operating temperatures from -20 °C to +60 °C. The mechanical life expectancy is at least 30 million switching operations, and the electrical life expectancy at 1 A/230 V is at least 150,000 switching operations.
Compatibility and accessories
The device is compatible with an optional alarm generator, designated as accessory IK/SK 8832. This can be controlled via the reset button QH to trigger an audible alarm. The bus lines H and S carry low voltage and must not be subjected to foreign voltages. In case of inductive or capacitive interference from high-current lines, the use of shielded cables is recommended, with the shielding connected to PE.
Mounting and installation
Mounting is done via a DIN rail (DIN standard), enabling quick and secure fixation in enclosures. The connection terminals are designed for conductor cross-sections of 2 x 2.5 mm² (solid) or 2 x 1.5 mm² (stranded wire with ferrule according to DIN 46228). The tightening torque is 0.8 Nm. Connections A1, S1–S4 and QH must be connected to the same phase, as well as the normally open contacts 13–14 and 23–24. The housing protection rating is IP 40, and the terminals are rated IP 20.
Advantages in operation
The IL5990 offers flexible input configuration, clear optical indication, and a robust construction for industrial use. The expandability up to 160 inputs enables a scalable solution. The integrated reset button and the possibility to operate the alarm generator externally increase user-friendliness. Compliance with DIN 19235 ensures standardized and reliable functionality in monitoring systems. EMC requirements are met, including protection against static discharge, HF radiation, and fast transients.