| Technical data |
| 1- / 2-channel | 2 |
| Approvals | UL |
| Cat. / PL acc. to EN ISO 13849-1 | 3/e |
| Classification | For initiators |
| Forcibly guided output contacts max. | 1 NC contact, 2 NO contacts |
| SIL CL acc. to IEC/EN 62061 | 3 |
| SIL acc. to IEC/EN 62061 | 3 |
| Thermal current Ith max. | 4 A |
| Width | 45 mm |
| Type | BH 5932 |
| Variant |
| Contact equipping | 2 NO contacts, 1 NC contact |
| Nominal voltage | AC/DC 24 V |
| Response value | 30 IPM |
| Approvals and Markings | UL-listed C/US, TÜV, CCC |
| Variant | Without sensor detection. NPN-input. Fixed setting value |
The Dold speed monitor BH5932.22/61 AC/DC24V 30IPM is a safety-relevant monitoring switch for continuous monitoring of rotational and linear movements in machines and systems. It is designed to detect machine movements that may pose a hazard to personnel or the machine itself, and is specifically conceived for use in safety-critical applications. The device features a fixed trigger value of 30 IPM (impulses per minute) and is designed for operation with a nominal voltage of AC/DC 24 V. The width is 45 mm, enabling compact mounting in standard control panels.
Applications
The BH5932 is used in industrial systems where safe monitoring of drive movements is required. This includes, for example, machines with rotating parts, conveyor systems, or machine tools, where an unexpected stop or uncontrolled movement could cause damage or injury. The device is designed for initiators, meaning for use with proximity switches serving as sensors for motion detection.
Functions and equipment in detail
The device features a 2-channel design, enabling two independent monitoring channels. The contact configuration includes 2 NO contacts and 1 NC contact, with the contacts being forced-guided to ensure reliable signal transmission even under mechanical disturbances. The inputs are designed for NPN proximity switches, using the variant without initiator connection detection.
Technology explained simply
The speed monitor detects the movement of an initiator, such as an inductive proximity switch mounted on a rotating or linearly moving machine part. If the pulse frequency falls below the fixed trigger value of 30 IPM, the output is switched via the forced-guided contacts to trigger a safety function such as an emergency shutdown. The maximum thermal current rating is 4 A, enabling use with standard loads in industrial automation. The approvals UL-listed C/US, TÜV, and CCC confirm compliance with international safety standards.
Compatibility and accessories
The device is compatible with inductive proximity switches from the NA 5001, NA 5002, NA 5005, and NA 5010 series by Dold. In particular, types NA 5002.01.34 and NA 5005.01.34, which offer both pnp and npn outputs, are suitable for devices without initiator connection detection. Wiring is done via terminals In A / In B for the inputs and the output contacts, with connection colors (brown, blue, black, white) corresponding to electrical functions. The sensor cable length is 2 m, enabling flexible installation.
Mounting and installation
Mounting is done in standard control panels with a width of 45 mm. The terminals are designed for conductor cross-sections up to 2.5 mm², and stranded wires with ferrules and plastic collars according to DIN 46 228-1/-2/-3/-4 can also be used. Wiring must follow the specifications in the connection tables, with color assignments to functions (e.g., brown = positive, blue = negative, black = NO) to be observed. The devices are designed for industrial environments, with ambient temperatures ranging from -25 °C to +70 °C.
Advantages in operation
The BH5932 offers high safety performance with Category 3 and Performance Level e according to EN ISO 13849-1, as well as SIL 3 classification according to IEC/EN 62061. The forced-guided contacts ensure reliable signal transmission even under mechanical disturbances. The clear structure of the connection terminals and the use of standard proximity switches simplify installation and maintenance. The UL, TÜV, and CCC approvals ensure compliance with international safety standards.