Further information for Dold 0049455 BH5928.93 DC24V 0,3-3S safety relay
Technical data
1- / 2-channel
1, 2
Approvals
UL
Cat. / PL acc. to EN ISO 13849-1
4/e
Connection
Pluggable screw terminals
Output contacts max.
3 NO contacts, 3 NO contacts delayed
SIL CL acc. to IEC/EN 62061
3
SIL acc. to IEC/EN 62061
3
Thermal current Ith max.
5 A
Width
45 mm
Type
BH 5928
Cross fault detection
Suited as safety gate monitor
Variant
Contact equipping
3 NO contacts, 3 NO contacts off delay
Nominal voltage
DC 24 V
Time range
0,3 - 3 s
Approvals and Markings
UL-listed C/US, TÜV, CCC
Variant
With adjustable time delay
The Dold safety relay BH5928.93 DC24V 0,3-3S is an emergency stop module for use in safety-critical industrial applications. It serves the protective function for personnel and machinery, particularly in emergency stop circuits, where a stop category 1 can be achieved. The device is suitable as a safety door monitor and monitors, for example, sliding safety grilles. It features an adjustable time delay in the range of 0.3 to 3 seconds, making it suitable for applications with delayed reset behavior. The width is 45 mm, enabling compact mounting in standard control panels.
Applications
The safety relay is used in industrial plants where safe shutdown is required in hazardous situations. Typical applications include machines with moving parts that must be immediately stopped upon activation of an emergency stop button. The function as a safety door monitor enables monitoring of access areas, for example, sliding doors or safety grilles, which shut down the machine when opened. The 1- or 2-channel wiring allows flexible integration into existing safety concepts.
Functions and Equipment in Detail
The device has six output contacts: three immediate closing contacts (immediate contacts) and three delayed reset contacts. The time delay is adjustable and serves, for example, to ensure that machines do not immediately stop upon activation of an emergency stop button, but instead incorporate a short delay to confirm that the operation is actually interrupted. The status indicator for the delayed reset timing circuit, as well as LED indicators for power supply, channel 1/2, and time delay, enable visual monitoring of the operating status. The connection technology uses removable screw terminals, ensuring flexible and secure wiring. The conductor connections can be made with 2 x 1.5 mm² stranded wire with sleeve and plastic collar DIN 46 228-1/-2/-3/-4 or 2 x 2.5 mm² stranded wire with sleeve DIN 46 228-1/-2/-3.
Technology Explained Simply
The safety relay operates at a rated voltage of DC 24 V and is designed for use in industrial control systems. The cross-connection detection at the single-button (when buttons are connected to terminals S33–S34) detects faults in the control circuit, such as short circuits, and reacts accordingly to avoid false alarms. The choice between activation via the single-button at S33–S34 or automatic start function with bridge at S13–S14 allows application-specific configuration. The thermal current rating is maximum 5 A, defining the contact load capacity. The safety functions are designed according to international standards to ensure high reliability.
Compatibility and Accessories
The device is designed for use in safety systems complying with EN ISO 13849-1 (Category 4, Performance Level e) and IEC/EN 62061 (SIL CL 3, SIL 3). It is certified with approvals such as UL-listed C/US, TÜV, and CCC, confirming compliance with international safety standards. Compatibility with other safety components is provided, especially in systems requiring 1- or 2-channel wiring. Use as a safety door monitor is explicitly intended, allowing integration into systems with mechanical safety devices.
Mounting and Installation
Mounting is done in standard control panels with a width of 45 mm. The removable screw terminals facilitate installation and maintenance. The connection terminals are clearly labeled to ensure error-free wiring. The LED indicators support commissioning by visually displaying the operating status. Compliance with technical data, especially the maximum thermal current rating of 5 A, must be considered during installation.
Advantages in Operation
The safety relay offers high reliability through compliance with strict safety standards. The adjustable time delay allows application-specific adaptation, while cross-connection detection identifies faults in the control circuit and prevents the machine from being incorrectly shut down. The LED indicators facilitate diagnosis during operation, and the removable terminals support quick maintenance. The UL, TÜV, and CCC certifications ensure suitability for use in various markets.