Further information for Dold 0049170 BG5925.02/61 AC/DC24V emergency stop module
Technical data
1- / 2-channel
1, 2
Approvals
UL
Cat. / PL acc. to EN ISO 13849-1
4/e
Connection
Pluggable screw terminals
Output contacts max.
4 NO contacts
SIL CL acc. to IEC/EN 62061
3
SIL acc. to IEC/EN 62061
3
Thermal current Ith max.
5 A
Width
22,5 mm
Type
BG 5925
Cross fault detection
Suited as safety gate monitor
Variant
Contact equipping
2 NO contacts
Nominal voltage
AC/DC 24 V
Approvals and Markings
UL-listed C/US, TÜV, CCC
The Dold emergency stop module BG5925.02/61 AC/DC24V is a safety-relevant switching component for use in industrial plants, particularly for the protection function of personnel and machinery. It serves as an emergency stop module and is used in safety control systems to safely shut down the machine in hazardous situations. The device is designed for use in protection systems requiring high safety integrity and complies with the requirements of standards EN ISO 13849-1 and IEC/EN 62061. It is suitable as a safety door monitor, meaning it can be used to monitor sliding safety grilles or other movable protective devices.
Applications
The module is used in plants where safe shutdown is required in case of danger. This includes, for example, machines with moving parts protected by sliding safety grilles, or plants where an emergency stop button must immediately bring the machine into a safe state. The application takes place in industrial environments where compliance with safety standards and accident prevention are paramount. The function as a safety door monitor enables monitoring of access areas to ensure that the machine can only be operated when all protective devices are correctly closed.
Functions and Equipment in Detail
The device features a contact configuration with 2 normally closed contacts, used for controlling safety functions. The maximum number of output contacts is 4 normally closed contacts, with the exact configuration varying depending on the variant. The nominal voltage is AC/DC 24 V, making it suitable for standard industrial applications. The connection technology uses removable screw terminals, enabling flexible and secure connections. The terminals are designed for conductor cross-sections of 2 x 1.5 mm² stranded wire with sleeve and plastic collar DIN 46 228-1/-2/-3/-4 or 2 x 2.5 mm² stranded wire with sleeve DIN 46 228-1/-2/-3.
Technology Explained Simply
The module is designed for single- or dual-channel wiring, meaning it can be used for either a single safety function or for two independent channels. Cross-circuit detection is integrated to detect faults in the control circuit, such as short circuits between channels. This increases system reliability, as a fault in one channel cannot cause a malfunction in the other channel. The LED indicator displays the status of channels 1 and 2 as well as the power supply, which is helpful during commissioning and maintenance. Activation occurs via a single-button or an automatic start function, which can be set using switch S2. The cross-circuit detection in the emergency stop control circuit can be activated or deactivated via switch S1.
Compatibility and Accessories
The module can be combined with other safety components, especially in systems requiring redundant safety control. It is designed for use in safety circuits meeting the requirements of standards EN ISO 13849-1 and IEC/EN 62061. The certifications UL-listed C/US, TÜV, CCC confirm compliance with international safety standards. The module width is 22.5 mm, making it suitable for standard control panels. The maximum thermal current rating (Ith) is 5 A, defining the contact load capacity.
Mounting and Installation
Mounting is done in standard control panels with a module width of 22.5 mm. The removable screw terminals facilitate installation and maintenance. The connection terminals are designed to ensure a secure and durable connection. Setup is performed using switches S1 and S2, which control the cross-circuit detection and automatic start function. The LED indicators support commissioning by visually displaying the operating status.
Operational Advantages
The module offers high safety integrity with PL e and Category 4 according to EN ISO 13849-1 as well as SIL 3 according to IEC/EN 62061. The integrated cross-circuit detection increases system reliability by detecting and preventing faults in the control circuit. The LED indicators simplify diagnosis and maintenance. The use of removable terminals enables flexible and secure wiring. The module width of 22.5 mm fits standard control panels, simplifying integration into existing systems. The UL, TÜV, and CCC certifications confirm the device’s international usability.
Safety Standards and Certifications
The device complies with the requirements of standard EN ISO 13849-1 with Category 4 and Performance Level PL e. Additionally, it meets the requirements of standard IEC/EN 62061 with Safety Integrity Level SIL 3. The certifications UL-listed C/US, TÜV, CCC confirm compliance with international safety standards. These certifications are relevant for use in various markets and ensure compliance with respective safety regulations.
Application Examples
The module is used in plants where safe shutdown is required in case of danger. This includes, for example, machines with moving parts protected by sliding safety grilles, or plants where an emergency stop button must immediately bring the machine into a safe state. The function as a safety door monitor enables monitoring of access areas to ensure that the machine can only be operated when all protective devices are correctly closed. The application takes place in industrial environments where compliance with safety standards and accident prevention are paramount.