| Technical data |
| 1- / 2-channel | 1, 2 |
| Approvals | UL-Recognized |
| Cat. / PL acc. to EN ISO 13849-1 | 4/e |
| Connection | Pluggable screw terminals |
| Output contacts max. | 1 NC contact, 7 NO contacts |
| SIL CL acc. to IEC/EN 62061 | 3 |
| SIL acc. to IEC/EN 62061 | 3 |
| Thermal current Ith max. | 10 A |
| Width | 100 mm |
| Type | BN 3081 |
| Variant |
| Contact equipping | 7 NO contacts, 1 NC contact for feedback circuit |
| Nominal voltage | AC 230 V 50/60 Hz |
| Approvals and Markings | UL-rec. C/US, TÜV, CCC |
The Dold BN3081.63/61 AC50/60HZ 230V is an expansion module for safety applications in industrial environments. It is designed for safe and reliable contact multiplication and amplification of safety modules, particularly in conjunction with emergency stop systems. The device is intended for use in safety-critical installations, where monitoring of the feedback circuit plays a central role. The contact configuration includes
7 NO contacts and
1 NC contact for the feedback circuit, ensuring redundant and fail-safe signal transmission. The rated voltage is
AC 230 V at 50/60 Hz, making it suitable for use in standard industrial installations.
Applications
The expansion module BN3081 is used when more safety circuits are required than a single safety module can provide. It is particularly suitable for applications in machine and plant engineering, especially in combustion systems, where the standard
EN 50156-1 applies. Compliance with this standard ensures the reliability and safety of control units. The module can be operated in single- or dual-channel wiring, allowing flexible integration into existing safety architectures.
Functions and Features in Detail
The device features
removable screw terminals, enabling simple and secure wiring. The connection terminals are designed to ensure a secure connection even under industrial conditions. The
LED indicators for channel 1 and channel 2 allow visual monitoring of the operating status and facilitate troubleshooting. The contact configuration with 7 NO contacts and one NC contact for the feedback circuit ensures that the status of the safety circuit is continuously monitored, which is crucial for functional safety.
Technology Explained Simply
The fail-safe contacts ensure that the contact state cannot be changed uncontrollably even in the event of mechanical disturbances or wear. This is a key factor for safety in critical installations. The maximum thermal current rating is
10 A, defining the module’s load capacity under normal operating conditions. The width of
100 mm allows for compact mounting in standard control panels. The certifications
UL-rec. C/US, TÜV, CCC confirm compliance with international safety standards.
Compatibility and Accessories
The module is designed for use in conjunction with suitable switching devices and controls in safety applications. It is specifically intended for expanding safety modules already integrated into the system. Combining it with other Dold safety modules enables a scalable safety architecture.
Mounting and Installation
Mounting is performed in standard control panels with a width of 100 mm. The removable screw terminals simplify wiring and maintenance. The LED indicators support commissioning and ongoing monitoring. Installation is carried out in accordance with general safety guidelines and the manufacturer’s data sheet instructions.
Operational Advantages
Secure contact multiplication and amplification allow flexible expansion of existing safety systems without the need to install entirely new modules. Monitoring of the feedback circuit ensures high operational safety. The certifications according to
EN ISO 13849-1 (Category 4, PL e) and
IEC/EN 62061 (SIL 3) confirm suitability for safety-critical applications. The LED indicators and removable terminals enhance maintainability and efficiency during servicing.