| Technical data |
| 1- / 2-channel | 1, 2 |
| Approvals | UL-Recognized |
| Cat. / PL acc. to EN ISO 13849-1 | 4/e |
| Connection | Pluggable screw terminals |
| Output contacts max. | 1 NC contact, 7 NO contacts |
| SIL CL acc. to IEC/EN 62061 | 3 |
| SIL acc. to IEC/EN 62061 | 3 |
| Thermal current Ith max. | 10 A |
| Width | 100 mm |
| Type | BN 3081 |
| Variant |
| Contact equipping | 7 NO contacts, 1 NC contact for feedback circuit |
| Nominal voltage | AC/DC 24 V |
| Approvals and Markings | UL-rec. C/US, TÜV, CCC |
The Dold safety relay BN3081.63/61 AC/DC24V is an expansion module for safety applications, designed for the safe and reliable multiplication and amplification of contacts from safety modules. It features forced-guided contacts and is designed for use in industrial control systems, where monitoring of the feedback circuit plays a central role. The device is rated for operating voltages of AC/DC 24 V and offers a width of 100 mm, making it suitable for standard control panels.
Expansion module for safety systems
The BN3081 serves as an expansion module when more safety circuits are required than a primary safety module provides. It enables amplification and multiplication of contacts while maintaining safety functions such as feedback circuit monitoring. The contact configuration includes 7 normally closed contacts and 1 normally open contact, specifically designated for the feedback circuit. This configuration supports secure signal transmission in critical applications.
Functions and equipment in detail
The device is designed for 1- or 2-channel wiring, allowing flexible integration into different safety architectures. Connections are made via removable screw terminals, facilitating easy installation and maintenance. Two LED indicators show the operating status of channels 1 and 2, enabling visual monitoring of safety functions. The contacts are forced-guided, meaning they are mechanically designed so that one contact cannot close unless another is open — a key feature for safety functions.
Technology explained clearly
The safety functions of the BN3081 are certified according to international standards. It achieves Category 4 and Performance Level e according to EN ISO 13849-1, representing the highest requirement for safety functions in industrial applications. Additionally, it is certified up to SIL 3 according to IEC/EN 62061 and EN 61508, confirming its reliability in safety-critical systems. The maximum thermal current is 10 A, defining the contact load capacity. Certifications including UL-Recognized C/US, TÜV, and CCC confirm compliance with international safety standards.
Compatibility and accessories
The expansion module is intended for use in conjunction with suitable switching devices and controls in safety systems. It is particularly suitable for applications in combustion systems according to EN 50156-1. It is used in combination with primary safety modules that perform the actual safety function, while the BN3081 extends and amplifies the contacts.
Mounting and installation
Mounting is performed in standard control panels with a width of 100 mm. The removable screw terminals simplify installation and maintenance. The LED indicators allow for quick visual inspection of the operating status. The terminal assignment is detailed in the manufacturer’s datasheet, with contacts designated for secure signal transmission in the respective channels.
Advantages in operation
The BN3081 provides a reliable extension of safety functions without compromising safety integrity. The forced-guided contacts and certification to the highest standards ensure that safety functions operate even under critical conditions. The clear indication of channel status via LEDs supports maintenance and fault diagnosis. Use in combustion systems and other safety-critical systems is possible due to certifications and construction.