Further information for Dold 0048696 emergency stop module BO5988.61/024/61 DC24V+AC230V
Technical data
1- / 2-channel
1, 2
Approvals
UL-Recognized
Cat. / PL acc. to EN ISO 13849-1
4/e
Connection
Pluggable screw terminals
Output contacts max.
1 NC contact, 6 NO contacts
SIL CL acc. to IEC/EN 62061
3
SIL acc. to IEC/EN 62061
3
Thermal current Ith max.
10 A
Width
100 mm
Type
BO 5988
Cross fault detection
Variant
Contact equipping
6 NO contacts, 1 NC contact as signal contact
Nominal voltage
DC 24 V + AC 230 V
Time range
without
Approvals and Markings
UL-rec. C/US, TÜV, UKCA
Variant
Without time delay. Dual voltage model
The Dold BO5988.61/024/61 DC24V+AC230V is an emergency stop module of the BO 5988 series, developed for use in safety-critical systems. It serves the protection function for personnel and machinery and is particularly used in emergency stop circuits as well as for monitoring interlock gates. The device is designed as a dual-voltage variant, with the nominal voltage covering DC 24 V and AC 230 V. It features a width of 100 mm and is designed for use in enclosures. The contact configuration includes 6 NO contacts and 1 NC contact as a signalling contact, with the output contacts rated for a maximum thermal load of 10 A. The connection technology uses removable screw terminals, suitable for wires with 2 x 1.5 mm² (with sleeve and plastic collar DIN 46 228-1/-2/-3/-4) or 2 x 2.5 mm² (with sleeve DIN 46 228-1/-2/-3).
Applications
This module is intended for use in industrial systems, particularly in machine controls where safe shutdown in an emergency is required. It is used in emergency stop circuits to safely shut down the machine upon activation of the emergency stop lever or button. Monitoring of interlock gates enables detection of tampering or unauthorized access. The functions are designed to meet the requirements for safe control systems, particularly in systems certified according to standards EN ISO 13849-1 and IEC/EN 62061.
Functions and Equipment in Detail
The device offers 1- or 2-channel wiring, allowing flexible integration into various safety concepts. The cross-connection detection at the single button enables detection of faulty connections in the control circuit, increasing reliability. A feedback circuit X1-X2 is provided for monitoring external contactors to ensure they are correctly actuated. The integrated LED indicators for channel 1, channel 2, and power status allow visual monitoring of the operating state. Additionally, an integrated short-circuit and overvoltage protection is present to protect the device from damage due to electrical disturbances.
Technology Explained Simply
The safety functions of the module are based on standards EN ISO 13849-1 and IEC/EN 62061. It achieves a Performance Level (PL) e and Category 4 according to EN ISO 13849-1, representing the highest requirement for safety functions in mechanical systems. The SIL Claimed Level (SIL CL) 3 according to IEC/EN 62061 and SIL 3 certification according to IEC/EN 61508 confirm suitability for high-safety applications. The thermal current rating (Ith) is up to 10 A, indicating the maximum current the contact can withstand continuously without overheating. The dual-voltage design allows use in systems operating with both direct current (DC 24 V) and alternating current (AC 230 V).
Compatibility and Accessories
The module is designed for use in standardized enclosures and can be combined with other components of the BO 5988 series. It is without time delay, ensuring immediate shutdown. The removable terminal strips facilitate installation and maintenance. The approvals UL-Recognized C/US, TÜV, and UKCA confirm compliance with international safety standards.
Mounting and Installation
Mounting is carried out in standard enclosures. The removable screw terminals allow easy and secure connection of wires. The terminals are designed for the specified wire cross-sections. Positioning within the enclosure follows the electrical diagrams, ensuring correct connection of feedback circuits (X1-X2) and control lines. The LED indicators serve for visual control of the operating state.
Advantages in Operation
The module provides high safety integrity through certifications PL e, Category 4, SIL CL 3, and SIL 3. The integrated cross-connection detection and feedback circuit increase control reliability. The LED indicators enable quick diagnosis during operation. The dual-voltage design offers flexibility when integrating into existing systems. The removable terminals simplify maintenance and repair. The width of 100 mm allows compact mounting in enclosures.