| Technical data |
| Enclosure design | Distribution board |
| Output contacts max. | 2 C/O contacts |
| Thermal current Ith max. | 10 A |
| Width | 17,5 mm |
| Type | IK 8802 |
| Variant |
| Contact equipping | 2 changeover contacts |
| Nominal voltage | AC/DC 230 V |
| Variant | AC/DC 230 V, without LED |
The Dold coupling relay IK8802.12/023 AC/DC230V serves as an interface between control and power circuits in industrial systems and enables potential separation between control and load circuits. It is designed for use in installation distributors and is mounted on a DIN rail. The device has a width of 17.5 mm, making it suitable for use in standard enclosures. The contact configuration includes two changeover contacts designed for switching loads. The rated voltage is AC/DC 230 V, with an operating voltage range between 0.8 and 1.1 times the rated voltage. The thermal current rating (Ith) is up to 10 A, with each changeover contact rated for up to 5 A. These values apply for continuous operation in a temperature range of -20 °C to +55 °C. The pickup and drop-out times are each under 10 ms, enabling fast response to control signals. The relay complies with standards IEC/EN 61810-1 and IEC/EN 60947-5-1 and meets requirements for electrical and mechanical life. The electrical life is 250,000 switching operations for one changeover contact at 3 A and AC 230 V, and 50,000 switching operations for two changeover contacts. The mechanical life exceeds 50 million switching operations. The permissible switching frequency is 3,000 switching operations per hour. Short-circuit resistance is ensured by a maximum fuse rating of 6 A gG/gL for the variant with two changeover contacts. The housing design is for installation distributors, made of thermoplastic with V0 flammability rating according to UL Subj. 94. The housing protection rating is IP 40, and the terminals are protected to IP 20. The connection terminals are flat terminals with self-lifting connection washers, allowing connection of 2 x 2.5 mm² solid or 2 x 1.5 mm² stranded wire with ferrules according to DIN 46228-1/-2/-3/-4. The tightening torque is 0.8 Nm. Terminal identification follows EN 50005. The device is designed for operation at altitudes up to 2000 m above sea level. The operating temperature range is -20 °C to +55 °C, and the storage temperature range is -40 °C to +80 °C. The rated impulse voltage is 4 kV for input and output, and creepage and clearance distances correspond to pollution degree 3. EMC requirements are met according to IEC/EN 61000-4-2 to -4-6, including surge voltages and high-frequency radiation. Radio frequency interference suppression complies with Class B limits according to EN 55011. Vibration resistance is ensured with an amplitude of 0.35 mm and a frequency of 10 to 55 Hz according to IEC/EN 60068-2-6. Climatic resistance is tested according to damp heat testing per IEC/EN 60068-2-30. The device is supplied without LED indicator, as LED indicators are only available for variants with AC/DC 24 V. The device dimensions are 17.5 mm (width) x 89 mm (height) x 58 mm (depth). The net weight is 60 g. Switching capacities are defined according to AC 15 and DC 13: for closing contacts, the switching capacity is 3 A / AC 230 V, for opening contacts 1 A / AC 230 V. For direct current, the switching capacity for both closing and opening contacts is 1 A / DC 24 V. The arc limit curve shows the maximum permissible switching currents depending on voltage. The contact configuration is designed for use in industrial control systems, with the load limit curve defining the maximum switching values for the respective variant. The variant IK8802.12/023 is specifically designed for rated voltage AC/DC 230 V without LED indicator. Connection identification is via A1 (+) for the control signal and A2 for the neutral conductor, with load connections via contacts 11/12/14 and 21/22/24. Mounting is done on a DIN rail according to IEC/EN 60715. The device is designed for continuous operation and is suitable for applications in industrial automation where safe and reliable potential separation is required. Use in enclosures and distributors is standard. Technical data are valid for operation under the specified environmental conditions. Specifications refer to the technical status at the time of data sheet publication. Technical improvements and modifications are possible at any time.