Further information for Dold 0045884 voltage relay BA9036/010 AC50Hz 230V 0.5-10s
Technical data
1- / 3-phase
1
Auxiliary voltage
Without
Enclosure design
Switch cabinet
Nominal voltage max.
AC 400 V
Output contacts
2 C/O contacts
Width
45 mm
Type
BA 9036
Operate delay
Variant
Contact equipping
2 changeover contacts
Nominal voltage
AC 230 V 50 Hz
Time delay
0,5 - 10 s
Approvals and Markings
CCC
Variant
Overvoltage relay. Open circuit operation. With time delay
The Dold voltage relay BA9036/010 AC50HZ 230V 0,5-10S is an overvoltage relay of the VARIMETER series, designed for monitoring single-phase DC or AC power networks. It operates on the principle of operating current and features an adjustable time delay ranging from 0.5 to 10 seconds. Device settings are adjusted via rotary switches on the front panel, ensuring simple and user-friendly configuration. The relay enables early detection of voltage anomalies to prevent failures in electrical installations and enhance operational safety.
Applications
This relay is suitable for use in industrial and technical installations where continuous monitoring of network voltage is required. It is particularly suited for applications where stable voltage supply is critical, such as in automation systems, machine controls, or process industries. Monitoring is performed in the range of 24 to 400 V, with the nominal voltage for this variant being AC 230 V at 50 Hz. The maximum nominal voltage is AC 400 V.
Functions and Equipment in Detail
The device features 2 changeover contacts as output contacts, rated for switching operations in the AC 15 and DC 13 categories. The thermal current rating is 6 A, with switching capacity for make contacts at 2 A/AC 230 V and for break contacts at 1 A/AC 230 V. The electrical life at 6 A and AC 230 V is 150,000 switching cycles, while the mechanical life is 30 million switching cycles. The pickup delay is adjustable and activates when the voltage exceeds 0.6 times the nominal voltage. The reset values are also adjustable, with the reset ratio (hysteresis) ranging between 0.75 and 0.95 of the set value. The repeatability accuracy is ±0.5 % under constant parameters.
Technology Explained Simply
The relay monitors the applied voltage and responds when it exceeds the set value. The time delay allows short voltage fluctuations to be ignored, preventing false tripping. LED indicators show operational readiness (upper LED) and activation of the output relay (lower LED). The device design is intended for use in enclosures, with a width of 45 mm. The operating temperature ranges from -20 °C to +60 °C, both during operation and storage. The device complies with IEC/EN 60255-1 standards and meets requirements for monitoring technology in industrial installations.
Compatibility and Accessories
For variants with a DC voltage exceeding 60 V, an external resistor is required, connected to terminals e and z. The measured voltage is connected to terminals e and f. The devices are operational without auxiliary voltage, simplifying installation.
Mounting and Installation
The relay is mounted in enclosures and designed for continuous operation. The terminal connections are intended for wiring. Mounting follows standard practices for enclosure devices, with electrical and thermal safety requirements, especially when using an external resistor, to be observed. The resistor becomes very hot during operation, so sufficient clearance from adjacent components is required.
Operational Advantages
Early detection of voltage anomalies enables preventive maintenance and reduces the likelihood of failures. Adjustable pickup and reset values, along with time delay, offer flexibility in adapting to specific requirements. LED indicators facilitate visual monitoring of operational status. High mechanical and electrical life ensures reliable long-term use in industrial environments. Compliance with IEC/EN 60255-1 guarantees adherence to international standards for measurement and monitoring technology.