Technical data
1- / 2-channel
1, 2
Approvals
UL-Recognized
Cat. / PL acc. to EN ISO 13849-1
4/e
Connection
Pluggable screw terminals
Output contacts max.
1 NC contact, 3 NO contacts
SIL CL acc. to IEC/EN 62061
3
SIL acc. to IEC/EN 62061
3
Thermal current Ith max.
10 A
Width
45 mm
Type
BD 5935
Cross fault detection
Suited as safety gate monitor
Variant
Contact equipping
3 NO contacts, 1 NC contact
Nominal voltage
AC 110 V 50/60 Hz
Approvals and Markings
TÜV, UKCA, CCC
The Dold BD5935.48 AC110V 50/60Hz is a safety-oriented emergency stop module designed for use in industrial systems to enable safe interruption of circuits. It is particularly intended for protecting personnel and machinery in applications involving emergency stop buttons and safety doors. The device is configured as a safety relay and allows for 1- or 2-channel wiring, enabling flexible integration into various safety concepts. The width is 45 mm, allowing compact mounting in standard control panels.
Applications
This module is intended for use in safety-critical systems, particularly in manufacturing and processing industries. It is suitable as a safety door monitor, ensuring that machines are immediately switched off when a safety door is opened. The application is in systems requiring high safety integrity, such as emergency stop functions activated via pushbuttons or safety doors. Integration into safety circuits is achieved via the integrated circuit continuity detection, which monitors a defined state in the control circuit.
Functions and Equipment in Detail
The device features contact configuration with 3 NO contacts and 1 NC contact, making it suitable for various switching configurations. The contacts are gold-plated, ensuring reliable switching performance even under low-load conditions, such as signal transmission to PLCs. The cross-circuit detection in the emergency stop control circuit detects unauthorized connections between channels, preventing erroneous switching operations. Operational status indication is provided by LED indicators for Channel 1 and Channel 2, visually signaling the current state. Additionally, the device is equipped with overvoltage and short-circuit protection to enhance electrical safety.
Technology Explained Simply
The module operates at a rated voltage of AC 110 V at 50/60 Hz and is designed for operation in industrial networks. The maximum thermal current is 10 A, defining the contact load capacity. Connection is made via removable screw terminals, enabling quick device replacement and simplifying installation. The terminals are rated for conductor cross-sections up to 2.5 mm², and stranded wires with ferrules according to DIN 46228-1/-2/-3/-4 can also be used. The safety functions are certified according to international standards: it complies with Performance Level (PL) e and Category 4 according to EN ISO 13849-1, as well as SIL Performance Level (SIL CL) 3 according to IEC/EN 62061 and Safety Integrity Level (SIL 3) according to IEC/EN 61508. These certifications guarantee reliability in safety-critical operation.
Compatibility and Accessories
The module is designed for use in safety systems connected to emergency stop buttons, safety doors, or other safety switches. It can be operated in 1- or 2-channel configuration, with the 2-channel wiring providing higher safety redundancy. Connection options are standardized, allowing connection with standard wires and cables. The certifications TÜV, UKCA, CCC, and UL-Recognized confirm compliance with respective regional and international safety requirements.
Mounting and Installation
Mounting is performed in standard control panels with a width of 45 mm. The removable screw terminals facilitate installation and replacement. Connecting wires must be dimensioned according to technical specifications (e.g., max. 2.5 mm²). Device programming is done via the provided adjustment options, allowing selection between automatic single-function mode or activation via the start button. The LED indicators support commissioning and maintenance by visually displaying the operational status.
Advantages in Operation
The module offers high safety integrity through certification according to EN ISO 13849-1 and IEC/EN 62061. The integrated cross-circuit detection and overvoltage and short-circuit protection functions enhance reliability. The removable terminals allow for quick replacement, reducing maintenance time. The gold-plated contacts ensure stable switching performance, even under low loads. The operational status indication via LEDs simplifies diagnosis and maintenance during operation.