Dold 0044941, EAN: 4030641449414

Dold 0044941 time relay delayed return

Industrial Material > Industrial relays and contactors > Industrial Timers

Dold 0044941 time relay delayed return

Lieske Part No. 1583499
Mfg Part No 0044941
EAN-Code 4030641449414
Manufacturer Dold
Here only 126,23 EUR
150,21 EUR incl. VAT

Further information for Dold 0044941 time relay delayed return

Technical data
Enclosure designSwitch cabinet
Output contacts2 C/O contacts
Time function(s)Off-delay, with control signal
Width22,5 mm
TypeMK 9962
Variant
Contact equipping2 changeover contacts delayed
Nominal voltageAC/DC 24 V + AC 220 - 240 V
Time range0,15 - 3 h
VariantRelease delay, with control signal
The Dold MK9962 is a delay-on-dropout time relay with control signal, specifically designed for industrial applications in enclosure construction. It is used for time-delayed control of electrical loads, for example, when switching off motors, lighting systems, or other devices that require a defined delay time after the control signal is turned off. The variant AC/DC24V+AC220-240V 0.15-3H allows operation at two different voltage levels, with the delay time being continuously adjustable between 0.15 and 3 hours. The width of 22.5 mm makes the device compatible with standard DIN-format control panels.

Applications
This time relay is suitable for time-dependent controls in industrial automation, such as in manufacturing plants, building automation, or machine controls. It is used to ensure that certain functions only end after a defined time following the deactivation of a control signal. The delay-on-dropout function is particularly useful when a load must not be switched off immediately to avoid mechanical or thermal stress.

Functions and Equipment in Detail
The device features 2 changeover contacts as output contacts, which switch with delay. The delay time is adjusted via a continuous rotary switch on an absolute scale, enabling precise and easy adjustment. The repeatability is ≤ ±1 %, ensuring high reliability during repeated switching operations. Two LED indicators signal the device control status (upper LED) and the contact position (lower LED), simplifying fault diagnosis. Control is performed via potential-free terminals B1/B2, with no galvanic isolation from the operating voltage terminals A1/A2/A3 — therefore, control must be carried out using potential-free contacts.

Technology Explained Simply
When the control signal is switched on, the relay energizes and closes the output contacts. Once the control signal is removed, the timing cycle begins. After the set time has elapsed, the relay returns to its resting position. The time function is defined as delay-on-dropout with control signal, meaning the delay starts only after the control signal is switched off. The operating voltage can be connected at terminals A1/A2 (AC 220–240 V) and A3/A2 (AC/DC 24 V). The voltage influence values are ≤ ±0.5 %, ensuring stable operation even with voltage fluctuations within the permissible range (0.8–1.1 U_N). The temperature dependence is < ±0.1 %/K, which is very low and increases reliability in different environments.

Compatibility and Accessories
The device is designed for use in enclosures and complies with the standard EN 61812-1 for time relays. It is designed for continuous operation and can be used at an operating temperature of -20 °C to +60 °C. The maximum operating altitude is 2000 m above sea level. The contact material AgSnO₂ provides high switching capacity and long service life. The electrical life is at least 500,000 switching cycles at 5 A and AC 230 V, and the mechanical life is 30 million switching cycles. The short-circuit resistance is protected by a maximum fuse rating of 6 A gG/gL.

Mounting and Installation
The time relay is installed in an enclosure and connected to the operating voltage and control signal via the designated terminals. Terminals A1/A2/A3 are for the operating voltage supply, B1/B2 for the control signal, and contacts 15/16/18 and 25/26/28 for the output relays. Mounting is carried out in the usual manner for DIN control panels. The reset time is approximately 5 ms, enabling a quick response after switching off.

Advantages in Operation
The continuous adjustment of the delay time via a rotary switch and the clear indication via two LEDs simplify commissioning and maintenance. The high repeatability and low temperature dependence ensure stable operation. The dual-voltage design allows use in systems with different voltage levels. Compliance with standard EN 61812-1 and EMC tests (e.g. ESD, HF radiation, fast transients) guarantee safe and reliable operation in industrial environments.