Dold 0044938, EAN: 4030641449384

Dold 0044938 MK9962 time relay delayed return

Industrial Material > Industrial relays and contactors > Industrial Timers

Dold 0044938 MK9962 time relay delayed return

Lieske Part No. 1312747
Mfg Part No 0044938
EAN-Code 4030641449384
Manufacturer Dold
Here only 126,23 EUR
150,21 EUR incl. VAT

Further information for Dold 0044938 MK9962 time relay delayed return

Technical data
Enclosure designSwitch cabinet
Output contacts2 C/O contacts
Time function(s)Off-delay, with control signal
Width22,5 mm
TypeMK 9962
Variant
Contact equipping2 changeover contacts delayed
Nominal voltageAC/DC 24 V + AC 220 - 240 V
Time range0,5 - 10 min
VariantRelease delay, with control signal
The Dold MK9962 is a delayed-release time relay of the MINITIMER series, designed for industrial control applications. It features a dual-voltage configuration with nominal voltage AC/DC 24 V and AC 220–240 V, enabling flexible use in various mains voltage environments. The time function is designed as delayed release with control signal, meaning that the relay energizes and closes the output contacts upon activation of the control signal. Once the control signal is removed, a time-controlled reset begins, which can be adjusted via a continuously variable rotary switch in the range of 0.5 to 10 minutes. The setting is made on an absolute scale, allowing precise and repeatable adjustment of the delay time.

Applications
This time relay is suitable for time-dependent controls in industrial automation, for example, to delay switching operations, to secure machine sequences, or to control indicators. The delayed release with control signal function enables precise control of processes where a delay is required after switching off a signal. The operating voltage is supplied via terminals A1–A2–A3, while the control input B1–B2 must be operated potential-free, as there is no galvanic isolation from the operating voltage terminals.

Functions and Equipment in Detail
The device features two changeover contacts as output contacts, rated for loads up to 5 A (thermal current) at AC 250 V. The contact materials consist of AgSnO₂, ensuring high switching durability and good contact quality. The electrical life is at least 500,000 switching operations at 5 A and AC 230 V, while the mechanical life is 30 million switching operations. The repeat accuracy of the time delay is ≤ ±1 % of the set value, enabling high precision in repeated switching operations. The minimum switching-on time is 20 ms, and the re-readiness time is approximately 5 ms.

Technology Explained Simply
The time delay is adjusted via a continuously variable rotary switch, allowing simple and precise adjustment in the range of 0.5 to 10 minutes. The delayed release function means that the relay does not return to its resting position immediately after switching off the control signal, but only after the set time has elapsed. Control is performed potential-free via terminals B1–B2, where the control inputs are electrically connected to the operating voltage terminals. The operating voltage is supplied via A1–A2–A3, with voltage applied between A3–A2 (AC/DC 24 V) and A1–A2 (AC 220–240 V). The voltage ranges are 0.8 to 1.1 times nominal voltage for alternating current.

Compatibility and Accessories
The time relay is designed for use in enclosures and has a width of 22.5 mm, making it suitable for standard control panels. It complies with standard EN 61812-1 for time relays. Control is via potential-free contacts, with no galvanic isolation between control input and operating voltage. The output contacts are rated for an operating voltage of AC 250 V. The permissible switching frequency is 6000 switching operations per hour. The maximum short-circuit withstand requires a fuse with max. 6 A gG/gL.

Mounting and Installation
The device is mounted in enclosures and is designed for continuous operation. The operating temperature range is between -20 °C and +60 °C, and the storage temperature range is also between -20 °C and +60 °C. The operating altitude is limited to a maximum of 2000 m above sea level. The connection terminals are clearly labeled: A1–A2–A3 for operating voltage, B1–B2 for control input, and 15–16–18 and 25–26–28 for changeover contacts. The two integrated LEDs serve for fault diagnosis: the upper LED lights up when the control contact is connected, and the lower LED when the output relay is activated.

Advantages in Operation
The simple operation via the continuously variable rotary switch and the visual indication via LEDs facilitate commissioning and maintenance. The high repeat accuracy and long contact life ensure reliable operation. The dual-voltage configuration increases installation flexibility. Compliance with standard EN 61812-1 ensures reliability and safety of the device in industrial applications. The EMC requirements according to IEC/EN 61000-4-2 to -4-5 are met, enabling robust operation in electromagnetically stressed environments.
This is an offer of:

Lieske Elektronik e.K.

Reutener Str. 10
79279 Vörstetten

https://industry-electronics.com
Tel. 07666/88499-0
Fax. 07666/88499-111

Diesen Artikel finden Sie unter:
industry-electronics.com/artikel/1312747
qrcode für Dold 0044938 MK9962 time relay delayed return