Dold 0044932, EAN: 4030641449322

Dold 0044932 time relay delayed return

Industrial Material > Industrial relays and contactors > Industrial Timers

Dold 0044932 time relay delayed return

Lieske Part No. 126491
Mfg Part No 0044932
EAN-Code 4030641449322
Manufacturer Dold
Here only 126,23 EUR
150,21 EUR incl. VAT

Further information for Dold 0044932 time relay delayed return

Technical data
Enclosure designSwitch cabinet
Output contacts2 C/O contacts
Time function(s)Off-delay, with control signal
Width22,5 mm
TypeMK 9962
Variant
Contact equipping2 changeover contacts delayed
Nominal voltageAC/DC 24 V + AC 220 - 240 V
Time range0,05 - 1 s
VariantRelease delay, with control signal
The Dold time relay MK9962 AC/DC24V+AC220-240V 0.05-1S is a drop-out delayed industrial time relay from the MINITIMER series, designed for time-controlled applications in enclosures. It features a dual-voltage configuration and enables control of electrical loads with a delayed reset after deactivation of the control signal. The delay time is continuously adjustable via a rotary switch in the range of 0.05 to 1 second, with adjustment performed on an absolute scale. The repeatability is ≤ ± 1 %, ensuring precise and reproducible time control.

Applications
This relay is suitable for time-dependent controls in industrial plants, for example, to delay switching-off operations, to secure start-up or decay phases in machine controls, or to indicate operating states. Control is performed via potential-free terminals B1/B2, meaning there is no galvanic isolation between the control terminals and the operating voltage terminals A1/A2/A3. The operating voltage is supplied to terminals A3–A2 (AC/DC 24 V) and A1–A2 (AC 220–240 V).

Functions and Equipment in Detail
The device features two changeover contacts as output contacts, which switch with delay. The contact configuration consists of two changeover contacts, each comprising one normally open (NO) and one normally closed (NC) contact. The contacts are made of AgSnO₂, ensuring high switching durability and corrosion resistance. The rated operating voltage is AC 250 V, and the thermal current Ith is specified as 5 A. The electrical life is 5 × 10⁵ switching operations at 5 A and AC 230 V, while the mechanical life is 30 × 10⁶ switching operations. The maximum permissible switching frequency is 6000 switching operations per hour.

Technology Explained Simply
When the control signal is activated at B1/B2, the relay energizes and the output contacts switch to the energized position. Once the control signal is removed, the timing sequence begins. After the set delay time (0.05–1 s) has elapsed, the relay returns to its resting position. The time delay is adjusted via a continuously variable rotary switch, enabling simple and precise adjustment. The minimum energizing time is 20 ms, and the rearm time is approximately 5 ms. Voltage influence values are ≤ ± 0.5 %, and temperature influence is < ± 0.1 %/K, ensuring high stability under varying operating conditions.

Compatibility and Accessories
The relay is designed for use in enclosures and has a width of 22.5 mm. It complies with standard EN 61812-1 for time relays. Control is performed via potential-free contacts, with the control inputs B1/B2 electrically connected to the operating voltage terminals. The operating voltage can be either AC/DC 24 V (at A3–A2) or AC 220–240 V (at A1–A2). Approvals include an overvoltage category III and an insulation test voltage of 2.5 kV at pollution degree class 2.

Mounting and Installation
The device is mounted in standard enclosures, with a width of 22.5 mm ensuring compatibility with other components. The connection terminals are clearly labeled: A1/A2/A3 for operating voltage, B1/B2 for control input, and 15/16/18 and 25/26/28 for the two changeover contacts. Mounting is done via screw terminals, ensuring a secure connection. The operating temperature range is between -20 °C and +60 °C, and the storage temperature range is also between -20 °C and +60 °C. The operating altitude is limited to ≤ 2000 m.

Advantages in Operation
Simple operation and fault diagnosis are facilitated by two integrated LEDs—one for control signal (upper LED) and one for contact position (lower LED)—which simplify commissioning and maintenance. The LEDs illuminate when the control signal is active or when the output contacts are closed. The high repeatability and low dependence on voltage and temperature fluctuations ensure reliable operating results. EMC tests in accordance with IEC/EN 61000-4-2 to -4-5 ensure robust functionality in electromagnetically demanding environments.