Further information for Dold 0041660 surge relay EP5966 AC/DC24-60V UH DC24V 1S
Technical data
Alarm inputs
16
Alarm inputs extendable up to
160
Enclosure design
Front panel mounting
Operating principle
De-energized on trip, Energized on trip
Optical signal
LED
Width
72 mm
Type
EP 5966
Optional buzzer
Variant
Auxiliary voltage
DC 24 V
Operate delay
1 s
Signal voltage
AC/DC 24 - 60 V
The Dold EP5966 AC/DC24-60V UH DC24V 1S is a fault detection relay for monitoring industrial plants and buildings. It serves as a base unit for a fault monitoring system, which can be expanded via extension units EP5967 to include up to 160 fault detection inputs. The device is designed for front panel mounting and features a front surface of 72 x 144 mm. It operates with an auxiliary voltage of DC 24 V and detects alarm voltages in the range of AC/DC 24 to 60 V. The response delay is 1 second, which allows short-term disturbances to be suppressed.
Applications
This device is designed for monitoring technical installations in industrial environments as well as in buildings where visual and acoustic alarm indication is required in case of faults. It is particularly suitable for installations requiring central fault indication with acknowledgment capability and lamp test functionality. The expandability up to 160 inputs enables integration into larger systems, with extension units EP5967 being mountable in adjacent enclosures, limited to a distance of 10 meters.
Functions and Equipment in Detail
The EP5966 features 16 integrated fault detection inputs, divided into two groups of 8 inputs each. For each group, a choice can be made between the operating current principle (output relay activated in case of fault) and the standby current principle (output relay not activated in case of fault), with selection made via jumpers on terminals X3/X4 and X5/X6. Visual indication is provided by LEDs, with each fault having its own LED. Additionally, an LED for collective alarm indication is integrated. The labeling of the alarm lamps is done via an interchangeable scale designed for individual identification.
Technology Explained Simply
The fault detection inputs are not galvanically isolated from the power supply, so with DC supply, the negative pole must be connected to A2. The control line inputs are not protected against accidental connection to mains voltage. The 1-second response delay reduces false alarms caused by short-term voltage fluctuations. The inputs can optionally be supplied with different delay times (1 s, 3 s, 10 s) to adjust sensitivity. The relay outputs (normally open contacts) are used to control a sound alarm and a separate collective alarm indication outside the device.
Compatibility and Accessories
The device is compatible with expansion modules EP5967, each providing 16 additional fault detection inputs. The expansion units can be mounted in adjacent enclosures, with connections requiring shielding and the shield must be grounded on both sides. Plug-in terminal strips facilitate installation and maintenance. The functions acknowledgment (QH and QS) and lamp test (LT) can be performed via built-in and external buttons. The lamp test closes the collective alarm output contact 23-24 to check the functionality of the LEDs.
Mounting and Installation
The device is designed for front panel mounting and is installed in enclosures. The width is 72 mm. During installation, ensure that unused fault detection inputs in standby current mode are connected to the potential of the fault signals. Wiring of the control lines is done via terminals S1 to S16. The auxiliary voltage is connected to A1 and A2.
Operational Advantages
The system provides clear visual and acoustic fault indication with individual labeling capability. The acknowledgment function enables organized fault resolution, and the lamp test ensures the functionality of the indication. The expandability up to 160 inputs and the possibility to install expansion units in adjacent enclosures make the system flexible and scalable. The use of LEDs ensures long-lasting and energy-efficient indication.