Further information for Dold 0041635 emergency stop module BO5988.47/124 DC24V+AC230V 0,5-5S
Technical data
1- / 2-channel
1, 2
Approvals
UL-Recognized
Cat. / PL acc. to EN ISO 13849-1
4/e
Connection
Pluggable screw terminals
Output contacts max.
1 NC contact, 6 NO contacts
SIL CL acc. to IEC/EN 62061
3
SIL acc. to IEC/EN 62061
3
Thermal current Ith max.
10 A
Width
100 mm
Type
BO 5988
Cross fault detection
Variant
Contact equipping
3 NO contacts, 1 NO contact delayed, 1 NC contact as signal contact
Nominal voltage
DC 24 V + AC 230 V
Time range
0,5 - 5 s
Approvals and Markings
TÜV, UKCA
Variant
Auxiliary supply is not nesseary during elapse of time: tv adjustable. Dual voltage model
The Dold BO5988.47/124 is an emergency stop module of the BO 5988 series, specifically designed for use in safety-critical systems. It serves the protection function for personnel and machinery and is particularly used in emergency stop circuits as well as for monitoring interlock gates. The device features a dual-voltage configuration with rated voltage DC 24 V and AC 230 V, whereby no external power supply is required during the timing phase. The time delay is adjustable within the range of 0.5 to 5 seconds, making it suitable for applications requiring defined reset times.
Applications
This module is intended for use in industrial safety systems, particularly in machine controls designed according to safety function standards. It is used to ensure that when an emergency stop button is activated, the machine is safely shut down, and to allow resumption of operation only after a complete verification of safety conditions. The integrated cross-circuit detection at the single-button prevents an error in the control circuit from causing unauthorized restart.
Functions and Equipment in Detail
The device features contact configuration with 3 normally closed contacts, 1 delayed normally closed contact, and 1 normally open contact as alarm contact. The maximum number of output contacts is 6 normally closed and 1 normally open, with outputs rated for AC 250 V. The single- or dual-channel wiring allows flexible integration into existing safety architectures. The removable screw terminals facilitate installation and maintenance, with wire connections possible using 2 x 1.5 mm² stranded wire with ferrule and plastic collar DIN 46 228-1/-2/-3/-4 or 2 x 2.5 mm² stranded wire with ferrule DIN 46 228-1/-2/-3.
Technology Explained Simply
The module operates based on the principle of safe emergency stop function, where machine shutdown is triggered by a button. The delayed restart is achieved via the integrated time relay mechanism, which sets the time from 0.5 to 5 seconds. The restart circuits X1-X2 are used to monitor external contactors to ensure they function correctly. The integrated LED indicator for channel 1/2 and power supply visually indicates the operating status. The integrated short-circuit and overvoltage protection protects the device from damage due to electrical disturbances.
Compatibility and Accessories
The module is designed for use in systems complying with standards EN ISO 13849-1 (Category 4, Performance Level e) and IEC/EN 62061 (SIL CL 3, SIL 3). The certifications TÜV, UKCA, and UL-Recognized confirm compliance with applicable safety standards. It is available as a dual-voltage configuration, enabling flexible integration into different power supply systems. The width is 100 mm, making it suitable for standard control panels.
Mounting and Installation
Mounting is performed in standard control panels with a width of 100 mm. The removable terminal strips allow easy wiring. The connection terminals are designed for use with stranded wires according to DIN 46 228. Installation must follow the manufacturer’s technical instructions, ensuring correct wiring of safety functions.
Operational Advantages
The module offers high safety integrity by complying with SIL 3 and PL e standards. The integrated cross-circuit detection and restart circuit increase the reliability of the safety function. The LED indicators facilitate diagnostics during operation. The dual-voltage configuration and flexible wiring enable broad applicability in various industrial environments. The maximum thermal current rating is 10 A, sufficient for most industrial applications.
Certifications and Markings
The device carries the certifications TÜV, UKCA, and UL-Recognized, confirming compliance with European and international safety standards. Compliance with standards EN ISO 13849-1 (Category 4, PL e) and IEC/EN 62061 (SIL CL 3, SIL 3) ensures high safety performance. The width of 100 mm allows mounting in standard control panels.
Application Scenarios
The module is used in machine controls where safe shutdown and controlled restart are required. It is particularly suitable for systems with interlock gates, where restart is only permitted after full verification of safety functions. The cross-circuit detection at the single-button prevents an error in the control circuit from causing unauthorized restart.