| Technical data |
| 1- / 2-channel | 1 |
| Approvals | UL-Recognized |
| Cat. / PL acc. to EN ISO 13849-1 | 3/d |
| Connection | Screw terminals |
| Output contacts max. | 1 NC contact, 1 NO contact |
| SIL CL acc. to IEC/EN 62061 | 2 |
| SIL acc. to IEC/EN 62061 | 2 |
| Thermal current Ith max. | 8 A |
| Time delay max. | 30 s |
| Width | 45 mm |
| Type | BA 7924 |
| Variant |
| Contact equipping | 1 NC contact, 1 NO contact |
| Nominal voltage | DC 24 V |
| Time range | 0,3 - 3 s |
| Approvals and Markings | TÜV, CCC |
| Variant | 1 timing circuit, adjustable time |
The Dold delay module BA7924.21DC24V0,3-3S is an electronic component for time-delayed switching off in industrial control systems. It is used in safety applications where a controlled, delayed response to an input signal is required, for example, when switching off machines or plant components. The device operates at a nominal voltage of
DC 24 V and provides an adjustable time delay in the range of 0.3 to 3 seconds. The function is delayed reset, meaning that the output returns to the resting state not immediately after the input signal is switched off, but after a defined delay time. This is particularly important in applications where immediate switching off would be dangerous or disruptive to functionality.
Applications
The module is designed for use in safety-relevant systems, particularly in automation technology and machine control. It can be used in combination with suitable switching devices or controls to implement safety functions up to
PL d and
Category 3 according to EN ISO 13849-1, as well as up to
SIL 2 according to IEC/EN 62061. The application is in environments where high reliability and fault tolerance are required, for example, in manufacturing industry, packaging technology, or drive technology. The delayed reset function enables controlled switching off, which increases the safety of operating personnel.
Functions and equipment in detail
The device features contact configuration with
1 NO and
1 NC, which is mechanically interlocked. This ensures that the contacts are mechanically coupled, thus guaranteeing a secure switching state. The switching position indicator allows visual verification of the current state of the output relay. The time delay is adjustable and can be varied in the range of 0.3 to 3 seconds. The maximum time delay is 30 seconds, although the current variant is fixed to the range of 0.3–3 s. The connection technology uses
screw terminals, ensuring a secure and durable connection.
Technology explained simply
The delay module operates without auxiliary voltage, meaning it requires only the energy from the control voltage (DC 24 V) to function. The time delay is implemented by an integrated electronic timing circuit, which maintains a defined delay period after the input signal is switched off, before the output resets. The maximum thermal rating is
8 A, indicating the maximum current load for the contacts. The width is
45 mm, defining the mounting width in the enclosure and enabling installation on standard 35-mm rails.
Compatibility and accessories
The module is designed for use in safety systems and can be used in combination with suitable switching devices or controls. It is available in various variants, including models with redundant timing circuits or fixed time delays. The width of 45 mm allows installation in standard enclosures. The certifications
TÜV,
CCC, and
UL-Recognized confirm compliance with international safety and quality standards.
Mounting and installation
Mounting is carried out in standard enclosures on a 35-mm rail base. The screw terminals allow for simple and secure connection of the wires. The terminal assignment is described in the datasheet, with input and output lines clearly separated. The device indicators support commissioning and maintenance by visually displaying the current switching state.
Advantages in operation
The delayed reset function increases safety in systems by avoiding unexpected switching off. The mechanically interlocked contacts ensure high reliability, as contact breakage or incorrect switching states are excluded. The switching position indicator enables quick diagnosis during operation. The mounting width of 45 mm and the screw terminals simplify installation and maintenance. The certifications according to EN ISO 13849-1 and IEC/EN 62061 confirm suitability for safety-critical applications.