Further information for Dold 0037333 BD5987.02AC230V emergency stop module
Technical data
1- / 2-channel
1, 2
Approvals
UL-Recognized
Cat. / PL acc. to EN ISO 13849-1
4/e
Connection
Screw terminals
Output contacts max.
2 NO contacts
SIL CL acc. to IEC/EN 62061
3
SIL acc. to IEC/EN 62061
3
Thermal current Ith max.
10 A
Width
45 mm
Type
BD 5987
Cross fault detection
Suited as safety gate monitor
Variant
Contact equipping
2 NO contacts
Nominal voltage
AC 230 V 50/60 Hz
Approvals and Markings
TÜV
The Dold BD5987.02AC230V is an emergency stop module of the BD 5987 series, specifically designed for safety-oriented interruption of circuits in industrial applications. It serves as an electronic safety circuit and can be used, for example, in conjunction with emergency stop buttons or safety doors to protect personnel and machinery. The device is intended for use in installations with increased safety requirements, particularly in areas where safe and reliable shutdown is necessary, such as in manufacturing industry or elevator construction.
Applications
The module is suitable for use in safety-critical installations, particularly in applications requiring an emergency stop function or protection of safety doors. It complies with the requirements of Directive 2014/33/EU on lifts and can be used as a replacement for a safety switch according to EN 81-20, section 5.11.2.2. The function as a safety door monitor is explicitly confirmed, enabling integration into systems with movable protective covers or doors, automatically interrupting the circuit upon opening.
Functions and Equipment in Detail
The device features 2 normally closed contacts as output contacts, rated for a nominal voltage of AC 230 V 50/60 Hz. The contacts are gold-plated, ensuring reliable switching even under low loads, such as for signals to a PLC. Cross-circuit detection is activated, enabling detection of a short circuit in the emergency stop control circuit and appropriate response. Additionally, wire break detection at the single-button is integrated to identify faults in the control circuit early. The status is indicated via LEDs for channel 1, channel 2, and power supply, visually signaling the operating state.
Technology Explained Simply
The module operates with a screw terminal connection technology, ensuring a secure and mechanically stable connection. The maximum thermal current rating is 10 A, sufficient for most industrial applications. The width of 45 mm allows for compact mounting in standard control panels. The safety functions are certified according to EN ISO 13849-1 in Category 4 and PL e, representing the highest safety level for safety-related controls. Additionally, the device complies with SIL 3 according to IEC/EN 62061 and SIL 3 according to EN 61508, confirming its reliability in safety-critical systems. The integrated overvoltage and short-circuit protection function protects the device and connected components from damage due to electrical disturbances.
Compatibility and Accessories
The module is designed for single- or dual-channel wiring, allowing flexible integration into various safety concepts. It is suitable for use in elevator installations according to EN 81-20/-50 and meets the requirements of the relevant standards. Connection options include stranded wires with cross-sections up to 2.5 mm² with ferrules and plastic sleeves according to DIN 46 228-1/-2/-3/-4, ensuring broad compatibility with common cable types.
Mounting and Installation
Mounting is performed in standard control panels with a width of 45 mm. The screw terminals allow for easy and secure connection of wires. The terminal assignment is detailed in the manufacturer's datasheet. Installation requires no special tools, and the connection terminals are designed for use with stranded wires and ferrules. The LED indicators facilitate commissioning and fault diagnosis.
Advantages in Operation
The integrated cross-circuit detection and wire break detection enhance system safety and reliability by detecting faults in the control circuit early. The gold-plated contacts ensure long service life and reliable switching, even under low loads. Certification according to PL e, Category 4 and SIL 3 guarantees compliance with the highest safety standards. The LED indicators enable quick visual inspection of the operating status, simplifying maintenance and troubleshooting. The module is designed for use in industrial environments and meets the requirements for safety-related controls in manufacturing and machine building.