Dold 0035950 BA9043/003 undervoltage relay 3AC50-400Hz

Dold 0035950 BA9043/003 undervoltage relay 3AC50-400Hz

Lieske Part No. 1153817
Mfg Part No 0035950
EAN-Code 4030641359508
Manufacturer Dold
Here only 293,22 EUR
348,93 EUR incl. VAT

Further information for Dold 0035950 BA9043/003 undervoltage relay 3AC50-400Hz

Technical data
1- / 3-phase3
Auxiliary voltageWithout
Enclosure designSwitch cabinet
Nominal voltage max.3/N AC 690 / 400 V
Output contacts2 C/O contacts
Width45 mm
TypeBA 9043
Operate delayYes
Variant
Contact equipping2 changeover contacts
Nominal voltage3AC 525 V
Time delay0,5 - 10 s
Approvals and MarkingsUKCA
VariantFor 3p3w systems. With adjustable time delay
The Dold undervoltage relay BA9043/003 is a 3-phase monitoring device for three-phase networks without a neutral conductor. It is designed for continuous monitoring of the supply voltage and de-energizes output contacts in case of undervoltage to prevent damage to connected devices. The device is rated for nominal voltages of 3 AC 525 V and operates within a frequency range of 50 to 400 Hz. Measurement is performed via arithmetic mean value calculation, with phases L1 and L2 measured against L3, as no neutral conductor connection is present. Device settings are adjusted via rotary potentiometers on the front panel, allowing continuous adjustment of pickup and dropout values between 0.85 and 1.05 of nominal voltage, as well as hysteresis between 0.75 and 0.95 of the pickup value.

Applications
This relay is suitable for industrial applications and railway installations where reliable voltage monitoring is required. It is mounted in enclosures and designed for continuous operation. The operating temperature range is from -20 °C to +60 °C, and the storage temperature range is from -25 °C to +60 °C. The maximum operating altitude is 2000 m above sea level.

Functions and Equipment in Detail
The device features two changeover contacts as output contacts, each providing one normally open and one normally closed contact. The contact rating is up to 2 A at AC 230 V (normally open) and 1 A at AC 230 V (normally closed) according to IEC/EN 60947-5-1. The electrical life is 2 x 10⁵ switching operations at 3 A and AC 230 V. The mechanical life is specified as over 30 x 10⁶ switching operations. The contacts are rated for a thermal current of max. 6 A per contact. The switching delay is adjustable on this model and ranges from 0.5 to 10 seconds. However, the time delay is only effective if the voltage is at least 60 % of the nominal voltage; below 40 % of nominal voltage, the dropout occurs immediately.

Technology Explained Simply
The relay operates on the residual current principle, meaning the output relay is not energized during normal operation and only de-energizes in case of undervoltage. LED indicators signal operational readiness (red LED) and contact position (green LED). The device is insensitive to harmonics, meaning it operates reliably even during network disturbances caused by harmonics. Settings are adjusted via two rotary potentiometers on the front panel, allowing precise and user-friendly adjustment of values.

Compatibility and Accessories
The relay is designed for networks with or without a neutral conductor, with variant /003 specifically designed for systems without a neutral conductor. It is available for nominal voltages from 3 AC 100 V to 690 V, with the variant described here rated for 3 AC 525 V. The maximum overload capacity is 1.2 times nominal voltage continuously. The nominal frequency is between 50 and 400 Hz, with a frequency range of ±5 %. The devices comply with IEC/EN 60255-1 standards and carry the UKCA mark.

Mounting and Installation
The device is mounted on a DIN rail in accordance with IEC/EN 60715. The terminal connections are designed for 2 x 2.5 mm² rigid or 2 x 1.5 mm² flexible conductors with heat-shrink tubing. The terminals are equipped with M3.5 plus-minus screws with self-tightening clamps, with a tightening torque of 0.8 Nm. Dimensions are 45 mm width, 73 mm height, and 132 mm depth. Mounting is done via a DIN rail installed in the enclosure.

Operational Advantages
The adjustable time delay enables differentiated response to short-term voltage dips, avoiding unnecessary shutdowns. The LED indicators facilitate fault localization, as the operational status is visually identifiable. The ability to continuously adjust pickup and dropout values as well as hysteresis ensures precise adaptation to the specific application. Operation without auxiliary voltage reduces wiring complexity and the number of required components. The high mechanical and electrical life ensures long-term operation with minimal maintenance effort.