Dold 0035727, EAN: 4030641357276

Dold 0035727 BA9043/003 undervoltage relay 110V

Dold 0035727 BA9043/003 undervoltage relay 110V

Lieske Part No. 1153816
Mfg Part No 0035727
EAN-Code 4030641357276
Manufacturer Dold
Here only 293,22 EUR
348,93 EUR incl. VAT

Further information for Dold 0035727 BA9043/003 undervoltage relay 110V

Technical data
1- / 3-phase3
Auxiliary voltageWithout
Enclosure designSwitch cabinet
Nominal voltage max.3/N AC 690 / 400 V
Output contacts2 C/O contacts
Width45 mm
TypeBA 9043
Operate delayYes
Variant
Contact equipping2 changeover contacts
Nominal voltage3AC 110 V
Time delay0,5 - 10 s
Approvals and MarkingsUKCA, CCC
VariantFor 3p3w systems. With adjustable time delay
The Dold undervoltage relay BA9043/003 is an industrial device for monitoring 3-phase AC networks. It is designed for continuous monitoring of supply voltage and triggers a defined switching operation in case of undervoltage or voltage loss. The device is intended for three-phase networks without a neutral conductor and features an adjustable time delay ranging from 0.5 to 10 seconds. The rated voltage is 3AC 110 V, with the device suitable for rated voltages from 3/N AC 100/57 V to 690/400 V. Measurement is performed via arithmetic mean calculation, where in variants without a neutral conductor (such as BA9043/003), phases L1 and L2 are measured against L3. Device settings are adjusted via rotary potentiometers on the front, allowing continuous adjustment of pickup and drop-out values between 0.85 and 1.05 of the rated voltage, with a hysteresis of 0.75 to 0.95 of the pickup value.

Applications
This relay is designed for use in industrial and railway applications where reliable voltage monitoring is required. It is suitable for networks with frequencies from 50 to 400 Hz and is specifically designed for systems without a neutral conductor. The device is installed in enclosures, with a width of 45 mm enabling compact mounting on a DIN rail. The operating temperature ranges from -20 °C to +60 °C, and the storage temperature ranges from -25 °C to +60 °C.

Functions and Equipment in Detail
The device operates on the no-current principle, meaning the output relay is not activated in the event of a fault. The contact configuration includes two changeover contacts, rated for switching operations with a thermal current of up to 6 A per contact. Switching capacities are 2 A/AC 230 V for make contacts and 1 A/AC 230 V for break contacts according to IEC/EN 60947-5-1. The electrical life expectancy is at least 200,000 switching operations at 3 A/AC 230 V and cos ϕ = 1, while the mechanical life expectancy exceeds 30 million switching operations. The time delay is only active when the voltage is at least 60 % of the rated voltage; below 40 % of the rated voltage, drop-out occurs immediately.

Technology Explained Simply
Voltage monitoring is achieved by measuring individual phases against a reference. In the BA9043/003 variant, designed without a neutral conductor, phases L1 and L2 are measured against L3 to determine the arithmetic mean. Pickup and drop-out values are adjusted via rotary controls, enabling precise adaptation to specific applications. The time delay prevents false alarms during brief voltage dips. LED indicators show operational readiness (red LED) and activation of the output relay (green LED). The device is insensitive to harmonics and thus suitable for use in networks with high harmonic loading.

Compatibility and Accessories
The relay is suitable for networks with frequencies from 50 to 400 Hz and complies with IEC/EN 60255-1. It is intended for use in enclosures and is mounted on a DIN rail. The connection terminals are designed for 2 x 2.5 mm² rigid or 2 x 1.5 mm² flexible conductors with heat-shrink tubing. Mounting is done using M3.5 plus-minus screws with self-lifting inserts. The maximum overload capacity is 1.2 times the rated voltage continuously. The rated power consumption is 4 VA.

Mounting and Installation
Mounting is performed on a DIN rail in accordance with IEC/EN 60715. The connection terminals are designed for rigid or flexible conductors, with a stripping length of 10 mm. Mounting screws should be tightened with a torque of 0.8 Nm. Terminal markings include L1, L2, L3 (for supply connections) and 11, 12, 14 and 21, 22, 24 (for the two changeover contacts). The front of the device features adjustment knobs for pickup and drop-out values, as well as LED indicators.

Operational Advantages
Using this relay enables preventive maintenance, as voltage anomalies can be detected early. Rapid fault localization reduces downtime. Simple operation via rotary potentiometers and the absence of a need for a separate auxiliary voltage reduce wiring effort. Reliability under high switching cycles and robustness against electromagnetic interference (EMC Class III) make the device suitable for demanding industrial environments. Certifications UKCA and CCC confirm compliance with applicable safety and quality standards.
This is an offer of:

Lieske Elektronik e.K.

Reutener Str. 10
79279 Vörstetten

https://industry-electronics.com
Tel. 07666/88499-0
Fax. 07666/88499-111

Diesen Artikel finden Sie unter:
industry-electronics.com/artikel/1153816
qrcode für Dold 0035727 BA9043/003 undervoltage relay 110V