| Technical data |
| Enclosure design | Distribution board |
| Output contacts | 1 C/O contact |
| Time function(s) | On-delay |
| Width | 17,5 mm |
| Type | IK 7813 |
| Variant |
| Contact equipping | 1 changeover contact |
| Nominal voltage | AC 220 - 240 V |
| Time range | 1 - 10 s |
The Dold time relay IK7813.81 AC220-240V 1-10S is a delayed-action relay for industrial and installation control applications. It is used for time-controlled activation of loads, where the output contact switches only after a set delay time. The device is designed for use in installation distributors according to DIN 43880 and has a width of 17.5 mm, making it suitable for standard mounting slots. The rated voltage is AC 220 to 240 V, and the time range is fixed at 1 to 10 seconds. The time function is delayed-action, meaning the contact closes only after the set time has elapsed once the input voltage is applied.
Applications
This relay is suitable for applications requiring a time-delayed switching function, for example, to avoid inrush currents in motors, to control lighting systems, or to synchronize processes in manufacturing technology. The repeat accuracy of ≤ 1 % ensures reliable and reproducible time control. The LED indicator signals the state of the output relay, allowing visual monitoring of operation.
Functions and Equipment in Detail
The device features a changeover contact as the output contact, enabling switching with one normally closed and one normally open contact. The contact rating is designed for a rated operating voltage of AC 250 V. The contact materials consist of AgSnO₂, providing high switching durability and corrosion resistance. The contact reset time is less than 20 ms, enabling a rapid response when de-energized. The switching capacity is 10 A/AC 230 V for normally closed contacts and 5 A/AC 230 V for normally open contacts according to AC 15, which is sufficient for typical industrial loads.
Technology Explained Simply
The time delay is adjusted continuously via a relative scale. Changing the time setting during the timing process may cause unintended activation of the relay; therefore, adjustment is recommended only in the resting state. The reset time is less than 60 ms at 50/100 Hz, enabling rapid reset after de-energization. The voltage influence is ≤ 1 % with a voltage fluctuation of 0.8 to 1.1 times the rated voltage, ensuring stable operation even with slight supply voltage fluctuations. The temperature dependence is 0.05 % per Kelvin, indicating low dependency on ambient temperature.
Compatibility and Accessories
The relay is manufactured in the IK 7813 form factor, featuring a depth of 58 mm and bottom-mounted connection terminals for installation and industrial distributors according to DIN 43880. It is compatible with standard mounting slots and can be used in enclosures with mounting plates and cable ducts. The input voltage range is AC 220 to 240 V, with a voltage range of 0.8 to 1.1 times the rated voltage. The drop-out voltage is 15 % of the rated voltage, ensuring secure de-energization. The rated frequency is 50/60 Hz, with a frequency range of ±5 %.
Mounting and Installation
Mounting is performed in standard mounting slots with a width of 17.5 mm. The connection terminals are located at the bottom, enabling easy wiring. The devices are designed for continuous operation and can be used at an operating temperature of -20 to +60 °C. Storage is possible at -25 to +70 °C. The relative humidity is up to 95 % at 40 °C. The operating altitude is limited to ≤ 2000 m. The enclosure protection rating is IP 40, protecting against finger contact and solid objects larger than 1 mm. The connection terminals have a protection rating of IP 20.
Operational Advantages
The high mechanical life of over 30 million switching operations and the electrical life of 500,000 switching operations at 3 A/AC 230 V ensure long service life. The permissible switching frequency is 6000 switching operations per hour, suitable for intensive operating conditions. Short-circuit resistance is ensured with a maximum fuse rating of 10 A gG/gL and a circuit breaker with tripping characteristic B16. The EMC coverage includes immunity to electrostatic discharge (8 kV), RF radiation (12 V/m up to 1 GHz, 10 V/m from 1 GHz), fast transients (4 kV), and surge voltages (2 kV between supply lines, 4 kV between line and earth). Radio frequency interference suppression complies with Class B limits according to EN 55011. The insulation test voltage is 2.5 kV for 1 minute. The overvoltage category is III, and the rated impulse voltage is 4 kV at pollution degree 2. The creepage and clearance distances comply with requirements of IEC 60664-1.
The device complies with standard EN 61812-1 for delayed-action time relays. The rated power consumption is 3.5 VA at AC 230 V 50 Hz. The frequency range is ±5 % around the rated frequency of 50/60 Hz. The maximum thermal current load is 10 A, with the total current limit curve to be observed. The incandescent lamp load is 1200 W. The mechanical life is specified as over 30 million switching operations. The electrical life is 500,000 switching operations at 3 A/AC 230 V. The permissible switching frequency is 6000 switching operations per hour. Short-circuit resistance is ensured with a maximum fuse rating of 10 A gG/gL and a circuit breaker with tripping characteristic B16. The EMC coverage includes immunity to electrostatic discharge (8 kV), RF radiation (12 V/m up to 1 GHz, 10 V/m from 1 GHz), fast transients (4 kV), and surge voltages (2 kV between supply lines, 4 kV between line and earth). Radio frequency interference suppression complies with Class B limits according to EN 55011. The insulation test voltage is 2.5 kV for 1 minute. The overvoltage category is III, and the rated impulse voltage is 4 kV at pollution degree 2. The creepage and clearance distances comply with requirements of IEC 60664-1.