| Technical data |
| Approvals | UL |
| Enclosure design | Switch cabinet |
| Output contacts | 1 C/O contact |
| Time function(s) | Off-delay, without control signal |
| Width | 22,5 mm |
| Type | MK 9961 |
| Variant |
| Contact equipping | 1 NO contact undelayed, 1 changeover contact delayed |
| Nominal voltage | AC 230 V |
| Time range | 1,5 - 30 s |
| Variant | Release delay, without control signal |
The Dold time relay MK9961.35 is a drop-out delayed relay for use in time-dependent control systems without auxiliary voltage. It features a rated voltage of AC 230 V and an adjustable time range from 1.5 to 30 seconds. The contact configuration includes one instantaneous closer and one delayed changeover contact, with the function of the drop-out delayed relay operating without control signal. The device is designed for installation in enclosures and has a width of 22.5 mm, making it suitable for standard DIN rail mounting.
Applications
The relay is intended for applications in industrial control systems where a time-delayed shutdown is required after interruption of the operating voltage. Typical applications include motor control, lighting systems, or safety functions, where a controlled shutdown after a specific time interval is necessary. The zero-voltage security ensures that the relay maintains its function even during short-term voltage interruptions.
Functions and Equipment in Detail
The time delay is continuously adjustable and set on an absolute scale. Remote adjustment is possible via an external potentiometer, with a 4.7 MΩ potentiometer (part number 0003706) used for the time range of 1.5 to 30 seconds. The repeatability is less than ±1 %, enabling high precision in repeated switching operations. An LED indicator signals the presence of operating voltage.
Technology Explained Simply
The relay operates on the principle of drop-out delay: once the operating voltage is switched off, the output contact remains activated for the set time duration. The delay is achieved by an internal timing circuit that functions independently of auxiliary voltage. The contact materials consist of AgSnO₂ for the changeover contact and AgNi for the closer, ensuring high switching capacity and long service life. The thermal current rating is 2 A, and the switching capacity is 3 A/AC 230 V for the closer and 1 A/AC 230 V for the opener.
Compatibility and Accessories
The device is designed for mounting on DIN rails and can be combined with external potentiometers for remote adjustment. The permissible cable cross-section is 2 x 1.5 mm² for single- and multi-strand conductors with heat-shrink tubing according to DIN 46228. The terminal clamps are equipped with a self-lifting clamp piece to ensure a secure connection.
Mounting and Installation
Mounting is performed on a DIN rail (IEC/EN 60715). The terminal clamps are designed for connection with solid or stranded zinc-coated conductors. Fastening is done with a torque of 0.4 Nm. The operating temperature ranges from -20 °C to +60 °C, and the storage temperature corresponds to the operating temperature range.
Operational Advantages
The relay offers high repeatability and is designed for continuous operation. The zero-voltage security and the possibility of remote adjustment increase reliability and flexibility in use. The LED indicator facilitates diagnosis and maintenance. Compliance with standard EN 61812-1 and UL certification ensure conformity with international safety standards. The electrical life is 3 x 10⁵ switching operations at 3 A/AC 230 V, and the mechanical life is 50 x 10⁶ switching operations.
Approvals and Environmental Conditions
The device complies with standard EN 61812-1 and is UL certified. The overvoltage category is III, with a rated impulse withstand voltage of 4 kV at pollution degree 2. Insulation testing is performed at 2.5 kV for 1 minute. EMC requirements are met according to IEC/EN 61000-4-2 to -4-6. The enclosure rating is IP 40, and the terminals are IP 20. The operating altitude is limited to ≤ 2000 m.
Connection and Operation
The terminal clamps are assigned as follows: A1 (L/+) and A2 (N/-) for operating voltage, 15/16/18 for the delayed changeover contact, 23/24 for the instantaneous closer, Z1/Z2 for external potentiometer connection. The operating voltage range is 0.8 to 1.1 times the rated voltage. The drop-out voltage is 15 % of the rated voltage. The frequency deviation is ±5 % of the rated frequency (50/60 Hz). The minimum switching-on time is 80 ms. The permissible residual current is 10 mA. The rated consumption at AC 230 V is 9 VA.
Switching Capacity and Service Life
The switching capacity according to AC 15 is 3 A/AC 230 V for the closer and 1 A/AC 230 V for the opener. The electrical life at 3 A/AC 230 V is 3 x 10⁵ switching operations. The mechanical life is 50 x 10⁶ switching operations. The permissible switching frequency is 3000 switching operations per hour. Short-circuit resistance requires a maximum fuse rating of 4 A gG/gL.
Environmental Conditions
The operating temperature ranges from -20 °C to +60 °C, and the storage temperature corresponds to the operating temperature range. The operating altitude is limited to ≤ 2000 m. The climatic resistance corresponds to standard 20/060/04 according to IEC/EN 60068-1. Vibration resistance is 0.35 mm amplitude at frequencies from 10 to 55 Hz according to IEC/EN 60068-2-6. The enclosure is made of thermoplastic with V0 behavior according to UL 94.
Additional Technical Specifications
The creepage and clearance distances correspond to basic insulation with a rated impulse withstand voltage of 4 kV. Insulation testing is performed at 2.5 kV for 1 minute. EMC requirements are met according to IEC/EN 61000-4-2 to -4-6. Radio interference suppression complies with limit class B according to EN 55011. The enclosure rating is IP 40, and the terminals are IP 20. The terminal clamps are designed for 2 x 1.5 mm² conductors. Fastening is done with a torque of 0.4 Nm. Mounting is performed on DIN rails according to IEC/EN 60715. The weight is 140 g. Dimensions are 22.5 mm (width) x 82 mm (height) x 99 mm (depth).