Dold 0030371, EAN: 4030641303716

Dold 0030371 thermistor motor protection relay BA9038.11/003 240V

Dold 0030371 thermistor motor protection relay BA9038.11/003 240V

Lieske Part No. 1153678
Mfg Part No 0030371
EAN-Code 4030641303716
Manufacturer Dold
Here only 170,24 EUR
202,59 EUR incl. VAT

Further information for Dold 0030371 thermistor motor protection relay BA9038.11/003 240V

Technical data
ClassificationThermistor-Motorschutz
Enclosure designSwitch cabinet
Measuring range max.> 3 kΩ
Output contacts1 C/O contact, 2 C/O contacts
Width45 mm
TypeBA 9038
Variant
Auxiliary voltageAC 240 V
Contact equipping1 changeover contact
VariantWith thermal magnetic reclosing interlock (manual reset function)
The Thermistor motor protection relay BA 9038 from Dold is an enclosure device designed to prevent thermal motor overload. It is used to protect motors from damage caused by high switching frequency, heavy start-up, single-phasing, impaired cooling, or high ambient temperature. Additionally, it enables temperature monitoring of bearings, gearboxes, oils, and coolants. The device operates on the idle current principle, where the output relay is not activated in the event of a fault, and monitors the sensor circuit for wire breakage. The auxiliary voltage is AC 240 V, and the width is 45 mm. The variant BA9038.11/003 features a thermal-mechanical re-energizing lockout that is voltage failure-safe. When the trip temperature is reached, the output relay drops out, and after approximately 10 seconds, a button on the front panel pops out. The device can be reset to the monitoring position by pressing this button. It does not include an LED indicator.

Applications
This relay is designed for use in industrial plants where thermal overload of electric motors is a critical factor. It is particularly suitable for applications where the motor winding is equipped with special thermistors (PTC resistors). Up to six thermistors can be connected in series, with the pickup value set at a resistance of at least 3 kΩ and the reset value at a maximum of 1.8 kΩ. The connecting wires between the thermistor and terminals P1 and P2 must not be influenced by external voltages and should be routed in a separate cable. The total resistance of the wiring must not exceed 100 Ω.

Functions and Features in Detail
The device has an input for thermistors or bimetal contacts. The re-energizing lockout ensures that the output relay does not automatically reset even after normal temperature is restored, but only when the button is manually pressed. The BA9038.11/003 version includes a thermal-mechanical lockout that triggers the reset button approximately 10 seconds after tripping. The contact configuration is 1 changeover contact. The output contacts are rated for a thermal current load of 5 A. The switching capacity is 2 A / AC 230 V for the NO contact and 1 A / AC 230 V for the NC contact, according to IEC/EN 60947-5-1. For DC, the switching capacity is 1 A / DC 24 V, according to IEC/EN 60947-5-1.

Technology Explained Simply
The relay operates on the idle current principle, meaning the output contact is closed during normal operation and only opens when the pickup value (≥ 3 kΩ) is reached. Wire break detection ensures that a defective sensor circuit is also detected. The re-energizing lockout prevents the motor from restarting after an overload without manual confirmation, providing additional safety. Voltage failure safety means the lockout state is retained even in the event of a power failure.

Compatibility and Accessories
The relay is designed for use with special PTC resistors (thermistors) integrated into motor windings. It is compatible with auxiliary voltages of AC 24, 42, 48, 110, 127, 230, and 240 V. The standard IEC/EN 60947-8 is complied with. The contact configuration may include 1 or 2 changeover contacts depending on the variant. The width of 45 mm allows for installation in standard enclosures.

Mounting and Installation
The device is mounted in enclosures. The terminal markings are: A1/A2 for auxiliary voltage, P1/P2 for the input, 11/12/14 for the contacts of the first relay, and 21/22/24 for the contacts of the second relay. The total wiring resistance must not exceed 100 Ω.

Operational Advantages
The reliability of temperature monitoring is ensured by the idle current principle and wire break detection. The re-energizing lockout prevents unintended restarts after an overload. Voltage failure safety ensures that the protection status is maintained even during a power outage. The width of 45 mm allows for compact installation in existing enclosures. Compliance with the IEC/EN 60947-8 standard ensures conformity with industrial standards.
This is an offer of:

Lieske Elektronik e.K.

Reutener Str. 10
79279 Vörstetten

https://industry-electronics.com
Tel. 07666/88499-0
Fax. 07666/88499-111

Diesen Artikel finden Sie unter:
industry-electronics.com/artikel/1153678