Further information for Dold 0030028 voltage relay BA9037.12/001 230V
Technical data
1- / 3-phase
1
Auxiliary voltage
Without
Enclosure design
Switch cabinet
Nominal voltage max.
AC 400 V
Output contacts
2 C/O contacts
Width
45 mm
Type
BA 9037
Operate delay
Variant
Contact equipping
2 changeover contacts
Nominal voltage
AC 230 V
Time delay
without
Variant
Without time delay
The voltage relay BA9037.12/001 AC50/60HZ 230V from Dold is a single-phase monitoring device for DC and AC power networks. It is designed for continuous monitoring of under-voltage and over-voltage conditions within a voltage range of 24 to 400 V, with a nominal voltage of AC 230 V. The device is designed for use in enclosures and has a width of 45 mm, making it suitable for standard control panels.
Applications
This relay is intended for industrial and technical applications where the operational safety and availability of electrical systems are important. It is suitable for monitoring power supplies in machines, plants, lighting systems, or in building automation. Early detection of voltage deviations enables preventive maintenance and prevents damage to connected devices.
Functions and equipment in detail
The device features two changeover contacts as output contacts, which can be used to control auxiliary functions or alarms. The pickup and drop-out values are continuously and independently adjustable, with an adjustment range between 0.7 and 1.3 times the nominal voltage. The hysteresis is less than 4 % of the nominal value, ensuring precise switching behavior. The pickup delay is activated, thereby ignoring short-term voltage fluctuations and avoiding false alarms. The relay operates on the no-current principle, where the output relay is not activated in the event of a fault, increasing safety.
Technology explained simply
Measurement is performed directly at the voltage source to be monitored, without requiring an additional auxiliary voltage. The threshold values are adjusted via rotary controls, with the values for under-voltage and over-voltage being adjustable independently. The LED indicators signal operational readiness (upper LED) and activation of the output relay (lower LED). The devices are insensitive to harmonics, meaning they operate reliably even with non-sinusoidal voltage waveforms. The nominal frequency is 50/60 Hz, with a frequency tolerance of ±5 %.
Compatibility and accessories
The relay is designed for use in single-phase systems and complies with the standard IEC/EN 60255-1. The contact configuration with two changeover contacts allows control of two independent loads or signals. The terminals comply with DIN 46228-1/-2/-3/-4 and are designed for conductor cross-sections up to 2.5 mm² (solid) or 1.5 mm² (stranded). The switching capacity is 3 A for make contacts and 1 A for break contacts at AC 230 V, according to IEC/EN 60947-5-1. The electrical life expectancy is over 500,000 switching operations at 3 A and AC 230 V.
Mounting and installation
The device is mounted in enclosures and is designed for continuous operation. The operating temperature range is from -40 °C to +70 °C, and the storage temperature range is from -40 °C to +60 °C. The operating altitude is limited to a maximum of 2000 m above sea level. The terminals are equipped with self-loosening terminal pieces to ensure a secure connection. The protection rating is IP 40 for the housing and IP 20 for the terminals, providing protection against contact and dust, but not against water.
Advantages in operation
The combination of easy installation, high precision, and reliability makes the relay a robust solution for voltage monitoring. The avoidance of false alarms through pickup delay and the independent adjustment of pickup and drop-out values increase operational safety. The LED indicators allow for quick visual monitoring of the operating status. The EMC testing according to IEC/EN 61000-4-2 to -6 ensures good immunity against electromagnetic interference. The mechanical life expectancy exceeds 30 million switching operations, promising high long-term stability.