Further information for Dold 0029895 BA9036 DC32V voltage relay
Technical data
1- / 3-phase
1
Auxiliary voltage
Without
Enclosure design
Switch cabinet
Nominal voltage max.
AC 400 V
Output contacts
2 C/O contacts
Width
45 mm
Type
BA 9036
Operate delay
Variant
Contact equipping
2 changeover contacts
Nominal voltage
DC 32 V
Time delay
without
Approvals and Markings
CCC
Variant
Undervoltage relay. Closed circuit operation
The Dold voltage relay BA9036 DC32V is an undervoltage relay of the VARIMETER series, designed for monitoring single-phase DC or AC voltage networks. It enables early detection of voltage drops and thus supports the operational safety of electrical installations. The device setting is performed via rotary switches on the front, ensuring simple and user-friendly configuration. The device operates on the standby current principle, where the contact is closed in the resting state and opens in case of undervoltage. It is designed for use in enclosures and has a width of 45 mm, enabling compact mounting in standard switchboards.
Applications
This relay is suitable for voltage monitoring in industrial and technical installations, particularly in systems where stable voltage supply is critical. It monitors DC voltages up to DC 32 V and AC voltages up to AC 400 V. Applications include drive technology, pump control systems, lighting systems, or monitoring of emergency power supplies. The adjustable pickup and dropout values allow precise adaptation to the specific requirements of each installation.
Functions and Equipment in Detail
The BA9036 features 2 changeover contacts as output contacts, which can be used to control auxiliary functions or alarms. The contacts are rated for a thermal current of 6 A and meet switching capacities according to AC 15 (2 A / AC 230 V) and DC 13 (1 A / DC 24 V). The electrical life expectancy is 150,000 switching operations at 6 A and AC 230 V, while the mechanical life expectancy is 30 million switching operations. The pickup delay is adjustable between 0.5 and 10 seconds, and this function is only active when the voltage is above 60 % of the nominal voltage. The dropout ratio (hysteresis) is between 0.75 and 0.95 of the set value, ensuring stable switching behavior during voltage fluctuations.
Technology Explained Simply
The device operates without auxiliary voltage, meaning it is directly connected to the voltage source to be monitored. The setting is done via mechanical rotary switches that define the pickup and dropout values. The LED indicators signal operational readiness (upper LED) and contact position (lower LED), allowing visual verification of the operating state. The nominal consumption is 6 VA / 10 W, and the device is designed for an operating temperature range of -20 °C to +60 °C. The frequency range is ±5 % at a nominal frequency of 50 or 60 Hz.
Compatibility and Accessories
The relay is designed for use with DC voltages up to DC 32 V. For variants with DC voltages above 60 V, an external resistor is required, connected to terminals e and z. The measured voltage is connected to terminals e and f. The device complies with the standard IEC/EN 60255-1 and carries the certification CCC.
Mounting and Installation
Mounting is done in enclosures using screw fastening. The width of 45 mm allows compact placement in standard switchboards. The connections are clearly labeled, with terminals e, f, and z designated for voltage monitoring and the external resistor. Installation does not require additional auxiliary voltage, simplifying wiring. The LED indicators facilitate commissioning and ongoing monitoring of the operating state.
Advantages in Operation
By enabling early detection of voltage drops, the BA9036 allows for preventive maintenance and reduces the likelihood of failures. The adjustable values and pickup delay increase the reliability of the installation. The visual indication of contact position and operational readiness supports rapid fault localization. The device is designed for high mechanical and electrical life expectancy, ensuring operational safety over a long period. Compliance with IEC/EN 60255-1 guarantees adherence to international standards for measuring instruments in electrical installations.