Further information for Dold 0029536 voltage relay BA9036/012DC110V10S+RVD.FOLG.POS
Technical data
1- / 3-phase
1
Auxiliary voltage
Without
Enclosure design
Switch cabinet
Nominal voltage max.
AC 400 V
Output contacts
2 C/O contacts
Width
45 mm
Type
BA 9036
Operate delay
Variant
Contact equipping
2 changeover contacts
Nominal voltage
DC 110 V
Time delay
10 s
Approvals and Markings
CCC
Variant
Undervoltage relay. Closed circuit operation. With time delay
The Dold voltage relay BA9036/012DC110V10S+RVD.FOLG.POS is an undervoltage relay of the VARIMETER series, designed for monitoring single-phase DC and AC power networks. It is used for continuous monitoring of operating voltage in industrial and technical installations to detect voltage dips or failures early. The device operates on the standby current principle and is rated for a nominal voltage of DC 110 V. The integrated time delay of 10 seconds allows for an extended response time, ignoring short-term voltage fluctuations and triggering a reaction only in case of sustained disturbances. Adjustment is performed via rotary switches on the front, ensuring simple and user-friendly configuration.
Applications
This relay is intended for use in enclosures and is suitable for applications requiring high operational safety and reliability. Typical applications include monitoring of power supplies in production plants, machine controls, pump and fan systems, as well as in building automation. The single-phase monitoring makes it particularly suitable for single-phase networks, which are common in many industrial and commercial environments.
Functions and Equipment in Detail
The device features 2 changeover contacts as output contacts, used for protecting and controlling loads in electrical installations. The contacts are rated for a thermal current of 6 A and meet switching capacities according to AC 15 (make: 2 A / AC 230 V, break: 1 A / AC 230 V) and DC 13 (make: 1 A / DC 24 V, break: 1 A / DC 24 V). The electrical life expectancy is 150,000 switching operations at 6 A and AC 230 V, while the mechanical life expectancy is 30 million switching operations. The pickup delay is adjustable, ensuring the relay only reacts after a defined time when voltage drops below the set value. The dropout values are also adjustable and range from 0.75 to 0.95 of the set value, enabling hysteresis to avoid unnecessary switching operations.
Technology Explained Simply
The relay monitors the applied voltage and reacts when it falls below a preset threshold. Adjustment is done via rotary switches, allowing setting of pickup and dropout values within the range of 0.85 to 1.05 of the nominal voltage. For the variant /1_ _, the adjustment range is 0.9 to 1.25 of the nominal voltage. The LED indicators signal the operating status: the upper LED lights up when operating voltage is present, and the lower LED lights up when the output relay is activated. The width of 45 mm allows for compact mounting in standard enclosures. The device operates without auxiliary voltage, simplifying installation and reducing dependency on additional power sources.
Compatibility and Accessories
For operation with DC voltages above 60 V, such as DC 110 V here, an external series resistor is required, connected to terminals e and z. The measured voltage is connected to terminals e and f. For this variant, the series resistor ZWS 20 SL 1.5 kΩ 20 W is specified. The use of an external resistor is necessary to reduce the voltage to a level suitable for the relay. Approvals include CCC, and the device complies with the standard IEC/EN 60255-1. The maximum nominal voltage is AC 400 V, with the input voltage ranging from 24 to 400 V (AC) and 24 to 240 V (DC).
Mounting and Installation
The relay is designed for mounting in enclosures and is connected via the designated terminals. The connection terminals are clearly labeled, with terminal z exclusively intended for the external series resistor. Mounting is performed within a temperature range of -20 to +60 °C. The heat generation of the external series resistor requires appropriate mounting position with sufficient distance from adjacent components to ensure adequate cooling and shock protection.
Advantages in Operation
By detecting voltage dips early, the relay enables preventive maintenance and reduces the likelihood of system failures. The adjustable pickup and dropout values, along with the time delay, offer flexibility in adapting to different requirements. The LED indicators facilitate diagnosis and fault localization. Operational safety is enhanced by the reliability of the contacts and the high mechanical life expectancy. Productivity is increased by reducing downtime and enabling quick fault detection.