Technical data
Depth58 mm
Output contacts max.1 NO contact
Thermal current Ith10 A
Width17,5 mm
TypeIK 8814
ResettableYes
Time extension by long push button operationYes
Variant
Contact equipping1 NO contact, delayed
Nominal voltageAC 230 V
Time range0,5 - 10 min
The lighting timer switch IK8814.41AC50/60HZ230V0,5-10M from Dold is an industrial timer relay for modular mounting, which can be used as a stairway light automation, delayed-off timer relay, or delay switch. The device features an adjustable timing range from 0.5 to 10 minutes and is designed for a nominal voltage of AC 230 V. It operates via a static timing control and is designed for mounting on a DIN rail. The width is 17.5 mm and the depth is 58 mm, making it suitable for use in standard control panels.

Applications
This device is primarily intended for controlling lighting systems in buildings, especially as a stairway light automation, where it activates the lighting for a set duration upon pressing a pushbutton. It can also be used as a delay switch, for example, to keep a fan running after the lighting has been switched off. The delayed-off timer relay function allows for a delay in the return of the contact after the control pulse is switched off.

Functions and Equipment in Detail
The IK8814.41 features a single delayed-closing contact (1 NO contact), which moves into the active position upon pressing the pushbutton and runs the set time. During the timing period, the switch can be reactivated by pressing the pushbutton again, restarting the timing delay without interruption. This is particularly possible in a 4-wire circuit. An integrated slide switch on the front enables switching to continuous lighting, keeping the lighting active independently of the timing control. An LED indicator signals the active position of the contact.

Technology Explained Simply
The timing control is performed via a static timing element, ensuring a high repeatability accuracy of ±2 % of the scale end value. The nominal frequency is 50/60 Hz, and the voltage range is between 0.8 and 1.1 times the nominal voltage. The thermal current Ith is 10 A, indicating the maximum load capacity of the contact. The switching capacity is specified for lamp loads: up to 1200 W for incandescent lamps and 20 lamps at 58 W each for fluorescent lamps in dual circuit. The mechanical life exceeds 10⁶ switching operations.

Compatibility and Accessories
The device is restartable, meaning it can be reactivated during the timing period by pressing the pushbutton again. It is designed for control via a pushbutton, with both the pushbutton and the device connected to the same phase. The connection terminals comply with DIN 46228-1/-2/-3/-4 and allow connection of conductors with a cross-section of 2 x 0.6 to 2.5 mm² (solid) or 2 x 0.28 to 1.5 mm² (flexible). The stripping length is 10 mm.

Mounting and Installation
The lighting timer switch is designed for quick mounting on a DIN rail and can be mounted in rows. The operating temperature ranges from -20 °C to +45 °C, and the storage temperature ranges from -20 °C to +60 °C. The operating altitude is limited to a maximum of 2000 m above sea level. The housing protection rating is IP 40, and the terminals have an IP 20 rating. The vibration resistance is specified according to IEC/EN 60068-2-6 with an amplitude of 0.35 mm and a frequency of 10 to 55 Hz.

Advantages in Operation
The combination of adjustable timing, restart capability, and continuous lighting function offers flexibility in application. The LED indicator allows visual monitoring of the contact position. The high mechanical life and switching capacity for lamp loads make the device suitable for use in lighting systems. Compliance with standards EN 60669-1 and EN 60669-2-1 ensures safety and reliability in operation. The EMC requirements are met according to IEC/EN 61000-4-2 to -5, ensuring immunity against electromagnetic interference. Radio frequency interference suppression complies with limit class B according to EN 55011.

Functions and Equipment in Detail
The IK8814.41 is equipped with a delayed-closing contact, which moves into the active position upon pressing the pushbutton and runs the set time. The restart capability allows the timing delay to be restarted during the timing period. The continuous lighting function is activated via a slide switch on the front. The LED indicator signals the active position of the contact. The connection terminals are designed for conductor cross-sections of 0.6 to 2.5 mm² (solid) or 0.28 to 1.5 mm² (flexible). The stripping length is 10 mm.

Compatibility and Accessories
The device is designed for control via a pushbutton, with both the pushbutton and the device connected to the same phase. The restart capability allows the timing delay to be repeated during the timing period. The continuous lighting function is activated via a slide switch on the front. The LED indicator signals the active position of the contact. The connection terminals are designed for conductor cross-sections of 0.6 to 2.5 mm² (solid) or 0.28 to 1.5 mm² (flexible). The stripping length is 10 mm.

Mounting and Installation
The lighting timer switch is designed for quick mounting on a DIN rail and can be mounted in rows. The operating temperature ranges from -20 °C to +45 °C, and the storage temperature ranges from -20 °C to +60 °C. The operating altitude is limited to a maximum of 2000 m above sea level. The housing protection rating is IP 40, and the terminals have an IP 20 rating. The vibration resistance is specified according to IEC/EN 60068-2-6 with an amplitude of 0.35 mm and a frequency of 10 to 55 Hz.

Advantages in Operation
The combination of adjustable timing, restart capability, and continuous lighting function offers flexibility in application. The LED indicator allows visual monitoring of the contact position. The high mechanical life and switching capacity for lamp loads make the device suitable for use in lighting systems. Compliance with standards EN 60669-1 and EN 60669-2-1 ensures safety and reliability in operation. The EMC requirements are met according to IEC/EN 61000-4-2 to -5, ensuring immunity against electromagnetic interference. Radio frequency interference suppression complies with limit class B according to EN 55011.